Summary Information

Communication Driver Name: TTS08

Implementation DLL: T.ProtocolDriver.TTS08.dll

Interface: TCPIP

Protocol: The SD50 is a TCP/IP server that supplies a binary encoded sensor data stream on port 9876 and listens for parameter tare commands on port 9976

PC Hardware requirements: Ethernet board



Channel Configuration

Protocol Options

Not used in this driver

Settings

AcceptUnsolicited must be checked



Node Configuration

Station Configuration

Station syntax: <IP>;<Port>

Where:

  • <IP> = The SD50 IP Address
  • <Port> = 9876 must be set to receive the data stream



Point Configuration

Address

The syntax for the TTS08 communication points are: <SensorTxId>:<ItemID>

Where:

  • <SensorTxId> Sensor TxId in Hexa
  • <ItemID> Specific item to be read. See the list below:
    • Battery
    • Pressure
    • Tension
    • Torque
    • Temperature
    • X_Axis_Acceleration
    • Y_Axis_Acceleration
    • Z_Axis_Acceleration
    • RPM



Troubleshoot

The status of the driver's execution can be observed through the diagnostic tools, which are:

• Trace window
• Property Watch
• Module Information

The above tools indicate if the operations have succeeded or have failed. A status of 0 (zero) means communication is successful. Negative values indicate internal driver errors.