OmronFINS implements communication with CS/CJ/CP-series CPU Unit or NSJ devices that are compatible with FINS. It operates as a Master on UDP or serial networks. The communications blocks are dynamically created according to the pooling cycle defined on the AccessType for each Device Point.


Summary

Omron Master – using FINS Commands – UDP and RS232.

Communication Driver Information

Driver name

OmronFINS 

Implementation DLL 

T.ProtocolDriver. OmronFINS.dll

Protocol

FINS protocol

Interface

UDP and Serial

Supported Equipment

CS/CJ/CP-series CPU Unit or NSJ Controller

Tested Equipment

SYSMAC CJ2M CPU34 and CPU35 using UDP/FINS


Supported Operands

Supported Operands

Operand

Read 

Write

Data Type

Address size

CIO – CIO

Yes

Yes

Word

2 bytes

WR – Work Area

Yes

Yes

Word

1 bit

HR – Holding Bit

Yes

Yes

Word

2 bytes

AR - Auxiliary Bit

Yes

Yes

Word

2 bytes

DM – Data Memory

Yes

Yes

Word

2 bytes

TA – Timers

Yes

Yes

BCD

2 bytes

CA – Counters

Yes

Yes

BCD

2 bytes

EM# – Extended Memory

Yes

Yes

Word

2 bytes


Channel Configuration

Protocol Options

Mode: Determines the compatible equipment:

  • CS1: CS/CJ series compatible

  • CV: CV/CVM1 series compatible

Network: Represents the FINS network. This information is related to the Master

Node: Represents the computer Node in the FINS network. If the number 0 is specified, the driver assumes the last octet of the IP Address as the Node number (for UDP Interface)

Ignore Non Fatal Error: Indicates the driver's behavior when the PLC returns a non fatal error status of 64:

  • True: If it returns a Success with the 64 error code, set the tag quality to GOOD

  • False: If it returns a Failed with the 64 error code, set the tag quality to BAD




Node Configuration

PrimaryStation Configuration

Serial channels

Station syntax: <Network>;<Node>;<Unit Id>

Where:

  • <Network> = Represents the FINS network where the device is located

  • <Node> = Represents the device Node number in the FINS network

  • <Unit Id> = Represents the Device ID in the FINS network

E.g.: 0;1;0


UDP channels

Station syntax:<IP address>;<Port>;<Network>;<Node>

Where :

  • <IP address> = The IP address of the device in the network

  • <Port> = The UDP port where the device is listening (default is 9600)

  • <Network> = Represents the FINS network where the device is located

  • <Node> = Represents the Device Node number in the FINS network

E.g.: 192.168.1.101;9600;1;0


Note: When using multiple nodes, the UDP port must be different for each Node.




Point Configuration

The syntax for the OmronFins communication points is: <Memory Area>:<Address>

For more information about the valid operands, see Supported Operands.

E.g.:

  • CA:0 Memory Area = CA, Address = 0

  • CIO:20 Memory Area = CIO, Address = 20

  • EM0:1 Memory Area = Extended Memory 0, Address = 1

  • EM6:1 Memory Area = Extended Memory 6, Address = 1