This document has only the specific information about the device connection settings and its address syntax.
Refer to the User Guide for more information on the Device Module.
Summary
Communication Driver Information | |
---|---|
Driver name | IPC |
Assembly Name | T.ProtocolDriver.IPC |
Assembly Version | 1.0.0.8 |
Available for Linux | False |
Devices supported | Filmex and Varex extrusion |
Manufacturer | IPC |
Protocol | Proprietary over TCP/IP |
PC Requirements | Ethernet port |
Nodes Configuration
Station Configuration
Station syntax: <IP Adress> ; <Port>
Where :
- <IP Address>: IP address of the device
- <Port>: IP port of the device. Default port is 1505
E.g.: 192.168.1.1; 1505
Point Configuration
Address
The syntax for the communication points is: DB<Number>:<Word>
Where:
DB=Data Blocks.
- <Number>: is the group number of the configured Data Block.
- <Word>: is the word address.
E.g.: DB10:5
Driver Revision History
IPC Revision History | |
---|---|
Version | Notes |
1.0.0.8 | Initial release on new documentation standards. |
In this section...