This document has only specific information about the device connection settings and its address syntax. 

Refer to the User Guide for more information on the Device Module.

On this page:


Summary

Communication Driver Information

Driver name

TTS08

Assembly Name

T.ProtocolDriver.TTS08

Assembly Version

1.1.0.1

Available for Linux

False

Devices supported 

TTS08 family devices

Manufacturer

McCoy Global

Protocol

The SD50 is a TCPIP server that supplies a binary encoded sensor data stream on port 9876 and listens for parameter tare commands on port 9976

Interface

TCP/IP

PC Requirements

Ethernet port


Channels Configuration

Protocol Options

Not used in this driver.

Settings

  • AcceptUnsolicited must be checked.



Nodes Configuration

Station Configuration

Station syntax: <IP> ; <Port>

 Where:

  • <IP>: SD50 IP Address
  • <Port>:  9876 must be set to receive the data stream.



Points Configuration

Address

The syntax for the TTS08 communication points is: <SensorTxId>:<ItemID>

Where:

  • <SensorTxId>:  Sensor TxId in Hexa.  
  • <ItemID>: Specific item to be read, such as:
    • Battery
    • Pressure
    • Tension
    • Torque
    • Temperature
    • X_Axis_Acceleration
    • Y_Axis_Acceleration
    • Z_Axis_Acceleration
    • RPM



Driver Revision History

TTS08 Revision History

Version 

Notes

1.1.0.1

Initial release on new documentation standards.


In this section...