This document has only specific information about the device connection settings and its address syntax.
Refer to the User Guide for more information on the Device Module.
On this page:
Summary
Communication Driver Information | |
---|---|
Driver name | TTS08 |
Assembly Name | T.ProtocolDriver.TTS08 |
Assembly Version | 1.1.0.1 |
Available for Linux | False |
Devices supported | TTS08 family devices |
Manufacturer | McCoy Global |
Protocol | The SD50 is a TCPIP server that supplies a binary encoded sensor data stream on port 9876 and listens for parameter tare commands on port 9976 |
Interface | TCP/IP |
PC Requirements | Ethernet port |
Channels Configuration
Protocol Options
Not used in this driver.
Settings
- AcceptUnsolicited must be checked.
Nodes Configuration
Station Configuration
Station syntax: <IP> ; <Port>
Where:
- <IP>: SD50 IP Address
- <Port>: 9876 must be set to receive the data stream.
Points Configuration
Address
The syntax for the TTS08 communication points is: <SensorTxId>:<ItemID>
Where:
- <SensorTxId>: Sensor TxId in Hexa.
- <ItemID>: Specific item to be read, such as:
- Battery
- Pressure
- Tension
- Torque
- Temperature
- X_Axis_Acceleration
- Y_Axis_Acceleration
- Z_Axis_Acceleration
- RPM
Driver Revision History
TTS08 Revision History | |
---|---|
Version | Notes |
1.1.0.1 | Initial release on new documentation standards. |
In this section...