This document has only specific information about the device connection settings and its address syntax. 

Refer to the User Guide for more information on the Device Module.



Summary

Communication Driver Information
Driver nameTTS08
Assembly NameT.ProtocolDriver.TTS08
Assembly Version1.1.0.1
Available for LinuxFalse
Devices supported 

TTS08 family devices

ManufacturerMcCoy Global
ProtocolThe SD50 is a TCPIP server that supplies a binary encoded sensor data stream on port 9876 and listens for parameter tare commands on port 9976
InterfaceTCP/IP
PC RequirementsEthernet port

Channels Configuration

Protocol Options

Not used in this driver.

Settings

  • AcceptUnsolicited must be checked.



Nodes Configuration

Station Configuration

Station syntax: <IP> ; <Port>

 Where:

  • <IP>: SD50 IP Address
  • <Port>:  9876 must be set to receive the data stream.



Points Configuration

Address

The syntax for the TTS08 communication points is: <SensorTxId>:<ItemID>

Where:

  • <SensorTxId>:  Sensor TxId in Hexa.  
  • <ItemID>: Specific item to be read, such as:
    • Battery
    • Pressure
    • Tension
    • Torque
    • Temperature
    • X_Axis_Acceleration
    • Y_Axis_Acceleration
    • Z_Axis_Acceleration
    • RPM



Driver Revision History

TTS08 Revision History
Version Notes
1.1.0.1Initial release on new documentation standards.

In this section...

  • No labels