Overview

Displays List provides a data grid, commands, and actions to manage the displays in your solution. It allows users to export displays to a .jpg or the Library and import displays from a file. The interface also allows users to insert, rename, or remove displays from the list and sort the display records by name or date.

Creating a new display in this interface is pretty simple: Click the 'New item' button on the top-left data grid corner to open the 'New Display' popup window. Enter a name for the display, select a Rendering Engine, specify the PanelType and click the 'OK' button to confirm the new display creation.

On this page:


Display Modes

Pages, dialogs, and pop-up are different display modes, they share some common, but each one have a specific particularly or behavior. They are commonly used in application development to build intuitive and dynamic user interfaces.

This feature brings speed-up to your digital solution development, it allows you think more about business solution and less about codes.

Page

A Page is a Display that always remains open or opens, replacing the previous display, constituting an independent unit of information or functionality within an application. In summary, it is a screen that allows users to perform a specific action, in which access to the page is given from a navigation menu or through other links within the application.

Dialog

A Dialog is a display that opens on top of all other displays and stays open, blocking the use of other displays until the User closes it.

A dialog is a small window that appears on top of the main application window and requires user input before it can be dismissed. It is typically used to prompt users for confirmation or additional information before proceeding with an action. 

Dialogs can be modal, meaning the User cannot interact with the main application window until the dialog is closed.

Popup

A Popup is a small window that opens over a page, remaining on top, but the Users can still interact with the other pages. It displays additional information or functionality. And it can be triggered by a user action, such as clicking on a button or link, or they can appear automatically based on certain conditions. 

Popups can be modal or non-modal, often containing forms, menus, or other interactive components.

PopupWindow

A PopupWindow opens a completely independent Window with its border to show the display. 

A small, separate window appears on top of the main application window. It can display additional information or provide quick access to specific functionality, but they are not intended to be used for extended periods.



Properties Reference

The Display module has properties enabled as default for each display. These include Name, Engine, PanelType, as well as read-only properties like Preview, BuildStatus, BuildErrors, BuildMessage, and Description.

The table below provides a reference for the Display List properties:

Display List Properties

ID

A unique identifier for the display.

VersionID

The version identifier, indicating the specific iteration or release of the display.

Name

The name assigned to the display for identification and reference.

Engine

The rendering engine used for the display, such as WPF, HTML5, or both, with the Portable option.

PanelType

The type of panel used, typically Canvas or Dashboard, determining the layout style.

Mode

Read-only. Shows whether the display is used as a Page, a Popup, or as a Dialog. This is defined on Drawing Properties / Display Settings.

Preview

Read-only. Uses the MainPage display as the thumbnail.

Navigate

A function to navigate or link to other displays or elements within the application.

Size

Read-only. The size of the display defined in Draw.

Length

The length property, possibly referring to duration or a specific dimensional measurement.

OnResize

Read-only. Actions taken when the display is resized (Stretch Fill, Stretch Uniform, Responsive or NoAction). This is defined on Drawing Properties / Display Settings.

EditSecurity

Select which Security Permissions group have access to edit this display.

RunSecurity

Select which Security Permissions group have access to this display in runtime.

BuildStatus

Read-only. The current status of the display's build process, such as 'Complete', 'In Progress', etc.

BuildErrors

Read-only. Any errors encountered during the build process of the display.

BuildMessage

Read-only. Messages or notes associated with the build process of the display.

Level

The level or tier of the display, possibly indicating its complexity or hierarchy in the system.

Category

The category assigned to the display, used for classification and organization.

LockState

Read-only. The current lock state of the display, indicating if it's editable or locked for modifications.

LockOwner

Read-only. The user or entity that currently has the display locked, if applicable.

DateCreated

Read-only. The date when the display was initially created.

DateModified

Read-only. The date when the display was last modified.

Description

A brief description or summary of the display's purpose and features.


In this section:

The root page @parent could not be found in space v10.