Pre-defined Security groups

The platform comes with a few predefined Permission groups that you can use, or you can create your own.

  • Administrator
  • Guest
  • User
  • Engineering
  • Supervisor
  • Maintenance
  • Operator

Security Permissions properties

Column

Description

Name

Enter a name for the group. 

Edit

Select the modules users in the group can access when editing a project.

Run

Select the modules users in the group can access when using the runtime.

Description

Enter a description for the Permission group.


Edit permissions

It is possible to allow/deny a user to edit different project tabs in the Engineering Environment. The available options are shown in the image below.

Edit Permissions properties

Property

Description

Unrestricted

Select to allow all Edit Permissions

EditTags

Select to allow tag editing.

Historian

Allow edition in Historian module.

Security

Select to allow for the Security module access.

Alarms

Select to allow for the Alarms module access.

Scripts

Select to allow for the Script module access.

Datasets

Select to allow for the Datasets module access.

Displays

Select to allow for the Displays module access.

Reports

Select to allow for the Reports module access.

Startup

Select to allow Startup.

Publish

Select to allow Publish.

Settings

Select to allow for the Settings access.

Notes

Select to allow for the Notes access.

CreateTags

Select to allow tag creating.


Run permissions

It is also possible to allow/disallow a user to perform different actions during Runtime.

Run Permissions properties

Property

Description

Unrestricted

The user gets permission to do everything.

Test

Once selected, the user can run a Test.

Startup

Once selected, the user can run a Startup with all the modules. If not, the modules script, datasets, devices, and reports will not start.

Shutdown

Once selected, the user is able to shutdown the application

ClientStart

Once selected, the user is able to run all the modules in a startup. If not, the modules displays and devices will not start.

ClientShutdown

Once selected, the user is able to shutdown the application as a client.

StartTools

Once selected, the user can run the diagnostics tool, such as: property watch, trace window and module information. If it is not selected, the user is unable to start these tools.

ToolsSetValues

Once selected, the user gets the read-only permission in the diagnostics tool, such as: property watch, trace window and module information.

CreateUsers

Once selected, the user is able to create new user for the project.

SwitchApplication

If it is not selected, the user can not switch application, the taskbar disappears.

WebAccess

When the user has this permission, he can access the Web Client through the URL found in the Info → Redundancy → Web Client URL. If this option is not selected, the user cannot use the Web Client.