Overview
On this page:
Heading 2
Heading 3
Paragraph
Pre-defined Security groups
The platform comes with a few predefined Permission groups that you can use, or you can create your own.
- Administrator
- Guest
- User
- Engineering
- Supervisor
- Maintenance
- Operator
Security Permissions properties | |
---|---|
Column | Description |
Name | Enter a name for the group. |
Edit | Select the modules users in the group can access when editing a project. |
Run | Select the modules users in the group can access when using the runtime. |
Description | Enter a description for the Permission group. |
Edit permissions
It is possible to allow/deny a user to edit different project tabs in the Engineering Environment. The available options are shown in the image below.
Edit Permissions properties | |
---|---|
Property | Description |
Unrestricted | Select to allow all Edit Permissions |
EditTags | Select to allow tag editing. |
Historian | Allow edition in Historian module. |
Security | Select to allow for the Security module access. |
Alarms | Select to allow for the Alarms module access. |
Scripts | Select to allow for the Script module access. |
Datasets | Select to allow for the Datasets module access. |
Displays | Select to allow for the Displays module access. |
Reports | Select to allow for the Reports module access. |
Startup | Select to allow Startup. |
Publish | Select to allow Publish. |
Settings | Select to allow for the Settings access. |
Notes | Select to allow for the Notes access. |
CreateTags | Select to allow tag creating. |
Run permissions
It is also possible to allow/disallow a user to perform different actions during Runtime.
Run Permissions properties | |
---|---|
Property | Description |
Unrestricted | The user gets permission to do everything. |
Test | Once selected, the user can run a Test. |
Startup | Once selected, the user can run a Startup with all the modules. If not, the modules script, datasets, devices, and reports will not start. |
Shutdown | Once selected, the user is able to shutdown the application |
ClientStart | Once selected, the user is able to run all the modules in a startup. If not, the modules displays and devices will not start. |
ClientShutdown | Once selected, the user is able to shutdown the application as a client. |
StartTools | Once selected, the user can run the diagnostics tool, such as: property watch, trace window and module information. If it is not selected, the user is unable to start these tools. |
ToolsSetValues | Once selected, the user gets the read-only permission in the diagnostics tool, such as: property watch, trace window and module information. |
CreateUsers | Once selected, the user is able to create new user for the project. |
SwitchApplication | If it is not selected, the user can not switch application, the taskbar disappears. |
WebAccess | When the user has this permission, he can access the Web Client through the URL found in the Info → Redundancy → Web Client URL. If this option is not selected, the user cannot use the Web Client. |