The ControlLogix External TagProvider  TagProvider interfaces with AB Rockwell ControlLogix and CompactLogix devices. Configure this connection to integrate real-time data into applications, eliminating the need for manual tag creation. This setup provides a way to access and utilize data from ControlLogix or CompactLogix series in various applications.

On this page:

Table of Contents
maxLevel3minLevel2
stylenone


Configuration

Initiate the configuration process by navigating to Unified Namespace → ExternalTags Source and selecting

To set up a new TagProvider connection navigate to Unified Namespace/TagProvider Connections and press the add button to open the New TagProvider Connection dialog. You can also create your TagProvider Connection directly from the AssetTree. To do this, navigate to Unified Namespace/Assets Tree and press Image Added to open the New TagProvider Connection dialog. In the configuration dialog, select the AB Rockwell ControlLogix/CompactLogix devices on the Provider field and insert the required connection parameters, such as the device model, the IP address, port number, and slot number. Test the connection by pressing the "Test" button. After that, press the Ok button to finish the provider configuration, and it will create a folder automatically in the Assets Tree (Unified Namespace / Assets Tree).

Info

Ensure all details are accurate for a seamless connection. If unsure about specific settings, refer to your device's documentation or seek expert advice.


Image Added

Connection Parameters

Field

Description

Provider

Specifies the type of device or system with which the TagProvider will interface. In this case, it is AB Rockwell ControlLogix and CompactLogix devices.

Access Mode

Determines the permissions for interacting with tags: Read allows data reading, Write permits data writing, and ReadWrite enables both reading and writing.

Name

User-defined name for the TagProvider instance, used to identify the specific configuration in the system.

Description

A brief explanation of the TagProvider's purpose or the systems it interfaces with, providing context for its usage.

ProtocolOptions

A set of parameters that define specific communication settings for the connection to the device.



Field

Description

Model

Selects the specific model of the ControlLogix or CompactLogix device. Options include Others (generic settings), 1756-L8X (for the 1756-L8X series), and Micro850 (for Micro850 series).

MaxStringItemsPerBlock

Defines the maximum number of string items that can be included in a single block of data.

WaitingBetweenMsgs

Sets the delay time between consecutive messages sent to the device, helping manage communication load.

StringLegacy

Configures compatibility with legacy string formats used in older systems.

Connection

Defines the network settings for connecting to the device, including IP address, port, and slot number.



Field

Description

Test

Button to verify the connection settings, ensuring that the system can successfully communicate with the specified device.

IP

The IP address of the ControlLogix or CompactLogix device to establish a network connection.

Port

The network port number used for communication with the device.

Slot

Specifies the slot number of the processor within the ControlLogix or CompactLogix chassis

Image Removed

  1. Initiating Setup: Click on the designated button to set up the AB Rockwell ControlLogix/CompactLogix ExternalTags. A new configuration window will appear.

  2. Selecting Device Model: Choose the specific model of your device from the dropdown list. Available options include "1756 - L8X", "Micro 850", for other ControlLogix or CompactLogix models, you can select "Others".

  3. Configuration Details:

    • MaxStringItemsPerBlock: Define the maximum number of string items per block.
    • WaitingBetweenMsgs: Specify the waiting time (in milliseconds or other units) between messages.
    • StringLegacy: Input the legacy string details or enable/disable the legacy mode (depending on its function).
    • IP: Enter the IP address of your AB Rockwell device.
    • Port: Provide the port number where your device is communicating.
    • Slot: Specify the slot number where your module is located.
  4. After filling in all the necessary configuration details, click on the "Connect" or "Save" button (whichever is applicable) to complete the setup.

  5. Test your connection with Test button.
InfoEnsure all details are accurate for a seamless connection. If unsure about specific settings, refer to your device's documentation or seek expert advice

.



In this section: