Solution Example: AlarmChangeMessage.dbsln |
...
- Solution Name: Alarm
...
- Change Message
- Software Version:
...
- v10
- Keywords:
...
- Alarms, Message
Summary
This
...
solution example modifies the Alarm Message during Runtime.
Technical Information
In this
...
solution,
...
The definition of an AlarmItem has 3 mandatory fields: TagName, Condition and AlarmGroup. That means, the Tag value that will be evaluated, the alarm condition to be verified, and if there is an Alarm, which AlarmGroup will guide the tag processing behavior.
To create or modify AlarmItems: Go to Alarms → Items.
In order to apply custom action using .NET scripts, subscribe to notifications of Alarms and events. These notifications are typically used to send SMS or email warnings, execute custom calculations, add custom notification Messages or audio Alarms, text-to-speech audio Alarms, and to perform any kind of action defined by custom programming.
Select the method in the Notification Method column on Alarms → Groups.
The name of the method can vary; The important is the expected parameters.
Reference Information
...
an alarm is triggered when the value of Tag1 is set to 1. Additionally, the message will change if the value of Tag2 is set to 5 (or if it was previously set to 5) and will revert to the previous text if the value of Tag2 is no longer 5.
This change is implemented through the display’s CodeBehind, where you can adjust the properties of any Alarm Item as needed. The method used for this example is shown below.
Code Block |
---|
@Alarm.Item.<Your alarm name>.Message = "Your custom message"; |
The example also depends on knowing the tag state at any given moment. Therefore, it utilizes the DisplayIsOpen() method along with other Alarm properties, as shown in the code snippet below.
Code Block |
---|
public void DisplayIsOpen()
{
if (@Alarm.Item.ID0.State == 2)
{
if (@Tag.Tag2 == 5 && @Alarm.Item.ID0.Message == "Alarm Primary State")
{
@Alarm.Item.ID0.Message = "Alarm is Locked";
@Tag.Tag1 = 1;
}
if (@Tag.Tag2 != 5 && @Alarm.Item.ID0.Message == "Alarm is Locked")
{
@Alarm.Item.ID0.Message = "Alarm Primary State";
@Tag.Tag1 = 1;
}
}
}
|