What is the Device Module
The Device Module implements real-item data communication with a wide variety of field devices and industrial protocols.
The Device Module supports standard interfaces like OPC-UA, OPC-DA and MQTT, Hart, and many proprietary protocols to various PLCs manufacturers.
The connectivity also includes IT protocols, like SNMP and Ping, and connection with Historian tools, such as OSIsoft PI, GE Historian, InfluxDB and Canary.
Currently around 50 drivers are included at no extra charge in the platform, and our development team has experience with more than 200 communication protocols.
On this page:
Table of Contents maxLevel 3
Device Module Highlights
Tip |
---|
Connectivity is a key feature of the software platform |
Simplify your architecture by removing the needing for additional communication products (e.g. Kepware / Matrikon)
Easily setup a communications hub to support comms and logic between practically any device, any database, any historian, anywhere.
On-Premise, Edge or enterprise level, and to/from the cloud – we have you covered!
MQTT Broker and OPC Server are both built-in!
MQTT SparkPlug B and OPC-UA simulators expedite demos and prototyping.
Driver Toolkit allows our team, or any third-party, to easily add new interfaces.
Key concepts
Channels
The Channel defines a data source connection, using an specific Protocol driver (e.g. Modbus) and an Interface type (e.g. RS-232, TCP/IP).
The Channel may access multiple stations (e.g. field devices, PLC) using the defined protocol and Interface.
Nodes
Each station is called a Node. Each node has one or more data Points.
Points
Points are registers, I/O values or variables residing in field devices (Nodes). Data Points provide the specific values for tags to access. Each data Point is bound to a specific Tag in the Project configuration.
AccessType
Each data point is associated with an AccessType. This defines the rules for reading and writing values for that data point, such as the polling rate, whether a read is performed on startup, and whether you write values to that data Point.
Purpose and Key Concepts
Channels
The Device Module uses Channels to establish connections with field devices. Each channel is defined by a specific protocol driver and connection type, such as RS-232 or TCP/IP. Channels allow the module to access multiple devices (such as PLCs) using the defined protocol and interface.
Nodes
Each device connected to the system through channels is called a Node. Nodes can be individual devices or groups of devices. Each node contains one or more Points.
Points
Points are individual items that can be read or written from/to nodes. They can be registers, I/O values or variables residing in field devices (nodes). Each Point is bound to a specific Tag in the Project configuration.
AccessType
Each Point is associated with an AccessType, which defines the rules for reading and writing values for that Point, such as the polling rate, whether a read is performed on startup, and whether you write values to that Point. The AccessType allows users to configure how clients can access data points in the system.
Overall, the Device Module simplifies architecture by removing the need for additional communication products like Kepware/Matrikon and provides an easy-to-use communications hub that supports comms and logic between practically any device, database or historian anywhere.
Configuration Workflow
The typical configuration workflow for the Device Module has the following sequence:
Device Module Configuration Workflow | ||
---|---|---|
Action | Where | Comments |
Create Channels | Devices → Channels | Identify the required field devices and protocols the project requires, create channels accordingly. |
Create Nodes | Devices → Nodes | Identify the Network addresses and relevant information to all stations and devices that need connectivity. |
Map Tags to Point addresses | Devices → Points | Optionally, you can Copy Tags from Excel/CSV from Excel or execute Import Wizards. |
Create or Customize AccessTypes | Devices → AccessTypes | Optionally, you can optimize the communication, grouping Points with similar requirements to the same AccessType. |
Creating Channels
To create channels:
Go to Edit → Devices → Channels.
Click Create New.
The Create New Channel window displays.
Enter or select information, as needed.
Click OK. The channel is added as a new row in the table
Device Channel Creation Settings | |||
---|---|---|---|
Field/Column | Description | ||
Channel Name | Enter a name for the channel. The system allows you to know if the name is not valid. | ||
Protocol | Select the protocol this channel uses. | ||
Interface | Select the interface type for this channel.
| ||
Description | Enter a description for this channel.
|
To edit device channels:
Go to Edit → Devices → Channels.
To add or remove a column, right-click the column heading area and select or deselect columns.
Edit the fields on the row corresponding to the channel you want to modify.
Device Channel Configuration Properties | |||
---|---|---|---|
Field/Column | Description | ||
ProtocolOptions | Configure the options for this protocol. | ||
Settings | Configure the settings for this channel. The available values depend on the interface the channel is using.
| ||
Timeout | Configure the timeout options for this channel. Typically, keep the default value. | ||
IntialState | Select the initial state for this channel. Enabled: the channel is loaded and execution starts when the project starts. Disabled: the channel is loaded, but does not starts execution going the disabled state. Remote: the channel is local in a remote Computer defined that the Remote Settings. See more information at Remote Execution. Reserved: the channel is not loaded, it acts as the channel was temporarily deleted from the project. | ||
Remote Settings | Set the primary IP and backup IP to configure the remote computer where this channel will run | ||
Driver Version | The version of the current driver being used. |
Protocol Drivers
Native Protocols vs OPC
What are the benefits of supplying native protocols interfaces to PLCs, instead of just use OPC client and rely on external OPC server to get the date?
Some PLCs are using OPC UA as their native built-in protocol, certainly this question does apply to them, but to other equipments using proprietary protocols.
There are many scenarios when the native driver is more beneficial. Let us explore some of them:
Higher Performance
Instead of a direct connection, invariably adding one more application in the middle cause additional lag time. Further, the AccessTypes and the ability of parles execution (multi-threading) available in the Device Module allows optimized configuration not available in most OPC servers.
Cost Reduction
Most of the native drivers are included at no charge. The exceptions when there is a cost, it is typically quite smaller than the OPC server cost.
The OPC server still needs to use the Native Protocol Addresses
One misleading argument to use OPC is to hide the PLC address from the configuration. The reason it is misleading is that you need to use the native PLC address to setup the configuration of the OPC server anyway; you just duplicated the work load.
The exception here is if the OPC Server is already installed and serving multiple applications. In this case, the connection using the OPC Client to the centralized OPC server is recommended.
Another good option is to leverage the OPC Server included in the Module device for the Edge application. In this case, the project connects with the field device with the native protocol, still enabling its OPC Server functionality, so other applications can use the built OPC Server in the FrameworX to access the data.
Easier Field Maintenance and Deployment
As explained on the previous item, if the OPC Server was not in its place, adding one more "middle-man" is just stressing the deployment and maintenance procedures.
Improved technical support
Two points for potential failure or misconfigurations, and two independent suppliers, typically do not compare with a single environment and centralized support.
Available Communication drivers
The up-to-date list of Communication drivers is publics at docs.tasoft.com at the Communication Drivers section.
Additional driver can be created using the Drivers Toolkit.
Creating Nodes
Nodes are the devices or PLCs on the network that you communicate with. You can enter the settings for your nodes as usual through the Engineering Workspace. You can also import settings from an OPC server or from another data source. See "Importing PLC Addresses" below.To configure nodes:
Go to Edit → Devices → Nodes.
Enter or select information, as needed.
To add or remove a column, right-click the column heading area and select or deselect columns.
Device Node Configuration Properties | |||||
---|---|---|---|---|---|
Column | Description | ||||
Name | Enter a name for the node. The system lets you know if the name is not valid. | ||||
Channel | Select the channel for this node. For more information about the configuration for common protocols, click Help at the top of the tab. | ||||
PrimaryStation | Enter the information required to access the primary node, based on the protocol selected.
For Modbus protocol:
| ||||
BackupStation | Enter the information required, based on the protocol, to access the backup node. When the backupstation is defined and a communication failure occurs on the primary station, the system automatically attempts to establish communication with the backup station. | ||||
SyncDate | Date that the import was done (read only field). | ||||
SyncStation | Information about the station where the import was done - Station IP, Port and Slot - (read only field). | ||||
SyncSettings | Information about the settings used by the system to import the file (read only field). | ||||
Description | Enter a description for this node. | ||||
[Other columns] | For definitions of other columns that are available in many tables, see Common Column Definitions. |
Creating Points
Data Points define specific values for each node that can be accessed using tags. The number of data points you can configure is related to both the ProductModel that is configured for the project and your software license.
To configure data points:
Go to Devices → Points.
You can copy and paste tags from the Tag → Objects.
Enter or select information, as needed.
To add or remove a column, right-click the column heading area and select or deselect columns.
Device Points Configuration Properties
Field/Column
Description
TagName
Enter a tag name or click "..." to select a tag. You can also create a new tag.
Node
Select the node for this data point.
Address
Enter the register address which is based on the PLC and protocol for this data point and tag.
Note The Protocol options are dependent upon which protocol is selected. Select the protocol from the dropdown list at the top of the page, and press the HELP button to access the specific protocol's documentation.
DataType
Select the data type you want to use. Most protocols should use the native option. When native is used, the protocol will automatically handle the data conversion.
Selecting a different data type overrides the defaults. Some options may not be applicable to the selected node. Make sure you know the applicable data types.
Modifiers
If the PLC uses a different byte order, select the options you want. You can change the position bit, byte, Word, or Dword of the data that is communicated.
AccessType
Select the access type for this data point. You can define and configure the access types. See Access Types below.
Scaling
If you want to manipulate the tag value, select the options you want.
When the data is read in the Equation option:
- Div - The system will divide the register value by what you enter here.
- Add - The system will add the amount you enter here as an offset of the result of the division.
For a write operation, the calculations are the opposite (multiple by the Div value, then subtract the Add value).
Label A text that represents a label on the point
Importing PLC Addresses
When creating communication nodes and data points, you can import them if they are defined in another data source in the following ways:
You can copy and paste the contents of a table from Excel. The tables can have different columns or order, as long you include the title of the column in the copy and paste operations. The system will put the data in the expected columns, even if the order is different in the source and target tables.
You can import the data from csv files.
For Rockwell ControlLogix devices, you can import from L5k definition files.
You can use various Import Wizards from many data sources
For OSIsoft® PI database, there is a FactoryStudio version to share definitions.
A programming API is available that can populate the tables from code, even from runtime execution when it is necessary.
Access Types Configuration
Access types define the specific methods for reading and writing the values of each data point. This could be the polling rate, whether or not a read is performed on startup, and whether or not unsolicited input is accepted. FactoryStudio comes with a few predefined access types that you can use, or you can create your own.
To configure access types:
Go to Devices → AccessTypes.
Do one of the following:
To edit an existing access type, double-click a field.
To create a new access type, click Create New.
Enter or select information, as needed.
Device AccessType Configuration Properties
Field/Column
Description
Name
Enter a name for this access type.
Read
ReadPolling
Select when you want to enable read polling.
ReadPollingRate
Enter how often the address value is retrieved.
ReadTrigger
Enter an object property that tells the system when to read the value.
ReadOnStartup
When selected, the system reads the value on startup.
ReadStatus
Enter an object property that receives the status of the read communication.
ReadCompleted
Enter an object property that receives an indication that the reading is completed. The value will change between 0 and 1 every time a reading is completed.
Write
WriteEventEnable
Select to enable the writing of values to the PLC.
WriteEvent
Select when the value is written.
WriteTrigger
Enter an object property that tells the system when to write the value.
WriteStatus
Enter an object property that receives the status of the write communication.
WriteCompleted
Enter an object property that receives an indication that the writing is completed. The value will change between 0 and 1 every time a writing is completed.
Settings
AcceptUnsolicited
When selected, the system accepts values from the PLC, even if the polling time has not yet elapsed.
UseStaticBlocks
Select to use the block command field
BlockCommand
Enter a definition for each block that will be created. Check the driver documentation to see if the specific driver uses this field and the valid values.
Description
Enter a description for the access type.
One very efficient AcceesType is to read data when it is being used by the application. Go to the section OnDisplayOrServer for more information.
AnchorUsing Diagnostic Tools Using Diagnostic Tools
Using Diagnostic Tools
Using Diagnostic Tools | |
Using Diagnostic Tools |
After you start the project in the Startup window, select the diagnostic tools. These are: PropertyWatch (Watch), TraceWindow (Trace), and ModuleInformation (Info).
You can also start the diagnostic tools on the Run → Test and Run → Startup pages by left-clicking the desired tool's icon. If menus are enabled for the display, you can also access the tools menu.
Module Information
The Module Information tool provides information about the operation of the modules. If you choose the devices module and a specific channel, you will see information regarding the function of the communication channel.
The "Read Groups Information" is important because it provides information about the virtual reading groups, the run time of each item, the quantity of the readings, and the readings that have failed. It also reports on the code and date/time of the last error.
These are the typical steps to use the Module Information tool:
Go to Read Groups Information to look at the number of successful and failed communication events and in order to quickly identify the communication blocks.
If you have systematic errors in all of the blocks or status codes with negative values, it typically means you cannot access the remote device. Check if the node address is right.
If you have specific blocks with systematic errors, verify the tags and addresses that are connected to the blocks. Use the TraceWindow with the Device information to collect information about the communication errors.
For some protocols, like OPC, the discarded items will show as a wrong addresses in the configuration.
Keep in mind that you can only READ from a field device when an Enterprise application is running in test mode. This makes it useful to run the application with ONLINE CONFIGURATION enabled because you do not need to start and stop the driver when modifying the configuration. You can modify PLC addresses, AccessTypes, and most of the application, and you can see the results in real-time on your running application. You can use the Startup window or the PropertyWatch tool to start and stop only one module, instead of restarting the entire runtime system.
Property Watch
Property Watch is a diagnostic tool used to access the tags and internal properties of the system for reading or writing. Type the name of the property in the Object column, and its value will be found in the Value column.
For example, in the screen shown above, select Tag.Coils
or Device.Channel.modbus.Status
. The value of these objects will be shown. To the right side, additional properties are displayed for the selected object.
Info | ||
---|---|---|
| ||
For Module Information and Property Watch, there are negative error codes that represents specific messages that can help to find the root cause of the error. In the Module Information, refer to the LastErrorCode column. On Property Watch, refer to See below the list of negative error codes:
|
Trace Window
The Trace Window tool displays system messages in a data grid interface. If you enable the module devices in the settings, information will be available about the status of reads, writes, unsolicited input, TX frames (sent), and RX frames (received).
When checking the devices CheckBox in the Settings, enable only the ERROR, INFO, and Warning information. Do not enable the Debug information, or you will create too much data. For ControlLogix devices, it is very important to use this tool, as the system will present here the invalid addresses on the configuration.
If you click the settings button in the configuration dialog, you can select which message types and modules to display. You can see the data in the data grid or save it to a file. It is also possible to configure a tag in ObjectName, and click the Add button to display a menu to select that object and include it in the monitoring.
The Device Namespace
The Device namespace is the entry point for all objects related to the device module.
Info |
---|
For general information on namespace and object concepts, go to the section Objects and Attributes. |
The Device.Channel object lists all of the configured channels and their runtime properties.
The Device.Node object lists all of the configured nodes and their runtime properties.
The Device.AccessType object lists the defined access types and has options to execute synchronous calls on reading and writing to the device.
The following tag properties are updated based on the device module:
Example | |
---|---|
tag.tagName.DevicePoint | Device point address connected with this tag. |
Tip | ||
---|---|---|
| ||
See Namespaces Reference for the complete list of properties and available methods. |
In this section...
Page Tree | ||||
---|---|---|---|---|
|