Overview

DrillingChart is similar to TrendChart, but it is adapted for drilling operations. It also allows axes customization, label and grid line settings, pen configurations, and SPC settings. Users configure it by setting control names, binding tags, and defining pen properties. Usage involves selecting tag objects, setting up axes, and configuring visual elements for data display and interaction in monitoring production metrics and quality control.

On this page:

Table of Contents
maxLevel3
stylenone



Requirements

This component is Portable. It runs both on Windows (WPF) and on Web Pages hosted on any platform.


Configuration

  1. Go to Displays / Draw.
  2. On the Components Panel, select Charts, then DrillingChart.
  3. Click or drag-and-drop it on the Drawing area to use it.
  4. Double-click the object to open the configuration window.

DrillingChart Settings 

Control Name

Defines the name for the control, allowing it to be accessed via through the CodeBehind.

Bind to Tag

Specifies the object property where the Drilling configuration will be saved.

Bind Pens to Tag

Specifies the object property where the Pen values will be saved.

Orientation

Sets the orientation of the DrillingChart (Horizontal or Vertical). Options available:

  1. Horizontal: Sets the DrillingChart to display data horizontally.

  2. Vertical (Top to Bottom): Sets the DrillingChart to display data vertically, starting from the top and moving to the bottom.

  3. Vertical (Bottom to Top): Sets the DrillingChart to display data vertically, starting from the bottom and moving to the top.

Window

Sets the background color of the Drilling control.

Labels

Defines the color of the Drilling control labels.

Grid Lines

Sets the color of the grid lines in the Drilling control.

Grid Lines Stroke

Defines the settings for the grid line stroke.

Cursor

Enables or disables cursor settings in the Drilling control.

Mouse Actions

Enables or disables mouse actions on the Drilling control.

Marker Tooltip

Enables or disables tooltips for markers on the Drilling control.

AllowDrop

Enables or disables the ability to drop elements into the control area.


X Axis

The X-axis represents drilling parameters over time or depth.

Drilling X Axis configuration

Duration

Sets the time span for the X-axis defining a specific time window for the X-Axis and displays the Drilling over that period. In this mode, the X-Axis are representing time.

Depth

Configures a depth-based range for the X-axis values.

Labels

Specifies the number of labels on the X-axis.

Format

Controls how the time or value format appears defining the format of the X-axis labels.

Navigation Controls

Enables scrolling and zooming along the X-Axis, providing user-friendly data exploration.


Y Axis

The Y-axis typically assumes values related to physical or operational parameters measured during the drilling process.

Drilling Y Axis settings 

Y scale for each pen

Uses the min and max values of each pen for the Y-axis scale.

Y Range

Defines a fixed range for the Y-axis.

Labels

Specifies the number of labels on the Y-axis.

Format

Defines the format of the Y-axis labels.

Stack Y scales

Enables stacking of similar Y scales for easier comparison between pens.

Merge similar Y scales

Merges similar Y scales.

Using Y Axis Scaling

Considering:

Y-axis Min = 0;

Y-axis Max = 100;

The Drilling control allows many pens to be displayed together. When your pens do not have the same range, you can use the tips below to fit your data in the same chart and for better visualization:

  • If a pen has a lower range, 0 to 1 for example, you can set the max property of the pen to 1. When the real tag value is 1, the value 100 will be displayed in the chart. (100/1 scale).

  • If a pen has a higher range, 0 to 1000 for example, you can set the max property of the pen to 1000. When the real tag value is 1000, the value 100 will be displayed in the chart. (1/10 scale).

  • Added new property "FilterExpression" (string) in TDrillingChart and TTrendChart controls. This property is used with "select" command in where condition while getting samples from SQL historic.

  • Added new property "DisableXMinMaxChecking" (bool) in TDrillingChart control. This property is used to disable checking while scrolling X Axis, such as: depth < 0 and depth > current hole depth.

  • Created new properties and method in TDrillingChart and TTrendChart controls [only Windows Desktop]:

double RegionBeginPoint;

double RegionEndPoint;

DateTimeOffset RegionBeginDateTime [only GET];

DateTimeOffset RegionEndDateTime [only GET];

bool EnableRegionMode;

bool EnableRegionScroll;

Brush RegionOutsideBrush;

Brush RegionInsideBrush;

Brush RegionInsideStrokeBrush;

int RegionInsideStrokeThickness;

public void SetRegionDateTime(DateTimeOffset begin, DateTimeOffset end);

  • Add event handler while region is changed [only Windows Desktop]:

public event RegionChangedEventHandler RegionChangedEvent

  • Added new property "FilterExpression" (string) in TDrillingChart and TTrendChart controls. This property is used with "select" command in where condition while getting samples from SQL historic.

  • Added new property "DisableXMinMaxChecking" (bool) in TDrillingChart control. This property is used to disable checking while scrolling X Axis, such as: depth < 0 and depth > current hole depth.

  • Created new properties and method in TDrillingChart and TTrendChart controls [only Windows Desktop]:

double RegionBeginPoint;

double RegionEndPoint;

DateTimeOffset RegionBeginDateTime [only GET];

DateTimeOffset RegionEndDateTime [only GET];

bool EnableRegionMode;

bool EnableRegionScroll;

Brush RegionOutsideBrush;

Brush RegionInsideBrush;

Brush RegionInsideStrokeBrush;

int RegionInsideStrokeThickness;

public void SetRegionDateTime(DateTimeOffset begin, DateTimeOffset end);

  • Add event handler while region is changed [only Windows Desktop]:

public event RegionChangedEventHandler RegionChangedEvent


Pens

Pens represent individual data series, variables, or metrics that are displayed on the chart. Each pen typically has its own color, style, and scale.

Image RemovedLegend

Pens Properties 

ID

Identifier for each pen.

TagName

Sets the tag that provides the value for each pen.

PenSettings

Configures the pen settings, including line color, stroke, and marker type.

Expand
titlePen Settings

Image Added


MinValue

Defines the minimum value for the pen according to the Y-axis range.

Auto

Automatically sets the pen value based on the defined range.

MaxValue

Defines the maximum value for the pen according to the Y-axis range.

PenLabel

Sets the name of the pen. By default, the PenLabel is "*", which sets the label text to the value of the TagName field.

LimitMinMaxValue

Removes points less than the tag's Min value and greater than the tag's Max value.

Square

Fills the pen points with a square wave.

FilterLevel

Specifies the filter level to group points on the XY axis, calculating the average.

SPCEnabled

Defines the position of the legend in the Drilling control (e.g., RightPanel). Options available:

None: No legend is displayed.

TopLeft: Positions the legend at the top left of the drilling control.

TopRight: Positions the legend at the top right of the drilling control.

BottomLeft: Positions the legend at the bottom left of the drilling control.

BottomRight: Positions the legend at the bottom right of the drilling control.

RightPanel: Positions the legend in the right panel of the drilling control.

BottomPanel: Positions the legend in the bottom panel of the drilling control.

Enables the DrillingChart to display a set of extra pens describing the pen’s statistical process control (SPC).

SPCSettings

Defines what SPC pens to display. The following options are available:

Minimum: The minimum value in the tag’s history.
Maximum: The maximum value in the tag’s history.
Mean: The mean or average of values in the tag’s history.
Median: The middle value that separates the lower and upper halves of values in the tag’s history.
Sum: The sum of values in the tag’s history.
DeviationPlus (+ 2 Sigma): The mean plus twice the standard deviation of the tag’s history.
DeviationLess (- 2 Sigma): The mean minus twice the standard deviation of the tag’s history.



Runtime Execution

Runtime Execution

During runtime, the DrillingChart visualizes time-series data, enabling users to monitor and analyze data drilling effectively. Users have previously configured the Drilling Chart by setting control names, binding tags, and defining pen properties. They have also customized the Y and X axes, label and grid line settings, and SPC settings.

When the runtime environment is initiated, the DrillingChart displays the configured data. Users can interact with the chart, adjusting axes and visual elements to refine their data analysis. The DrillingChart dynamically updates to reflect real-time data changes, providing a comprehensive view of production metrics and quality control parameters. This tool facilitates detailed process monitoring and supports informed decision-making based on the visualized data.


In this section: