The GE Proficy Historian External TagProvider connects to GE Proficy Historian servers at runtime. Configure this External TagProvider to enable data integration and visualization without local Tags. This setup allows incorporation of GE Proficy Historian data into applications, enhancing data-driven decision-making and operational processes.

On this page:

Table of Contents
maxLevel3
minLevel2
stylenone


Configuration

To set up this Protocol GE Proficy Historian as an ExternalTagsExternal Tags source, navigate to Unified Namespaces  / External TagProvider, click on the "+" button and  and select the GE Proficy Historian Connector option.

Image Removed

Fill in the necessary fields:

Server: This is the address of the

To connect to the GE Proficy Historian

server to which you wish to connect

server, enter the server address in the Server. By default, it is set

as "

to localhost

",

but

this

you can

be changed

change it to any valid IP address or hostname. Next, input the required username in the Username field for authentication purposes. Finally, provide the corresponding password in the Password to complete the authentication process.

Image Added


Field

Description

Provider

Specifies the system the TagProvider will interface with. In this case, it interfaces with the GE Proficy Historian Connector.

Access Mode

Determines permissions for interacting with tags.

Read allows data reading.

Write permits data writing.

ReadWrite enables both reading and writing.

StoreAndForward

Enables the Store and Forward feature to buffer data locally when the server connection is lost.

Name

User-defined name for the TagProvider instance. Identifies the specific configuration in the system.

Description

Defines a short description for TagProvider's purpose or the systems it interfaces with. Provides context for its usage.

ProtocolOptions

Defines specific communication settings for the connection to the device. True or False.

Connection

Username: Enter the username required for authentication on

Defines connection string for the GE Proficy Historian, including server, username, and password.

Server

Specifies the server name where the GE Proficy Historian is hosted.

Username

Specifies the username for authentication with the GE Proficy Historian server.

Password

: Provide

Specifies the password

associated

for authentication with the

previously entered username.After entering the required details, save the settings, test the connection with a Test button

GE Proficy Historian server.

Test

Verifies the connection settings to ensure successful communication with the specified server.



In this section: