This document has only the specific information about the device connection settings and its address syntax.
Refer to the User Guide for more information on the Device Module.
Summary
WirelessHart communication driver implements communication with Emerson devices using HartIP protocol. It operates as a Master on TCP/IP networks.
Communication Driver Information | |
---|---|
Driver name | WirelessHart |
Assembly Name | T.ProtocolDriver.WirelessHart |
Assembly Version | 2.0.0.8 |
Available for Linux | False |
Devices supported | Emerson WirelessHart devices |
Manufacturer | Emerson |
Protocol | HartIP |
Interface | TCP/IP |
PC Requirements | Ethernet port |
Supported Commands
Command | Read | Write |
Command 0 – Read Unique Identifier | Yes | - |
Command 3 – Read Dynamic Variables and Loop Current | Yes | - |
Command 9 – Read Device Variables and Status | Yes | - |
Command 13 – Read Tag, Descriptor and Date | Yes | - |
Command 20 – Read Long Tag | Yes | - |
Command 38 – Reset Configuration Changed Flag | Yes | - |
Command 48 – Read Device Additional Status | Yes | - |
Command 50 – Read Dynamic Variable Assignments | Yes | - |
Command 74 – Read I/O System Capabilities | Yes | - |
Command 84 – Read Sub-Device Identity Summary | Yes | - |
Command 101 – Read Sub-device to Burst Message Map | Yes | - |
Command 105 – Read Burst Mode Configuration | Yes | - |
Command 178 – Publish Dynamic Data | Yes | - |
Channels Configuration
Protocol Options
Not used in this driver.
Node Configuration
Station Configuration
Station syntax: <IP address> ; <Port number>
Where:
- <IP address>: IP address of the Hart gateway
- <Port number>: TCP port where the gateway is listening (default is 5094)
E.g.: 192.168.0.107;5094
Point Configuration
The syntax for the communication points is: <DeviceTag>.<Command>: <Parameter>
E.g.: Acoustic708-050001.178:PVDeviceVariableValue
Where :
- <DeviceTag>: It will be brought from Hart gateway.
- <Command>: Hart Commands. See the table below for the availables command.
Command | Description |
0 | Read Unique Identifier |
3 | Read Dynamic Variables and Loop Current |
9 | Read Device Variables and Status |
13 | Read Tag, Descriptor and Date |
20 | Read Long Tag |
38 | Reset Configuration Changed Flag |
48 | Read Device Additional Status |
50 | Read Dynamic Variable Assignments |
74 | Read I/O System Capabilities |
84 | Read Sub-Device Identity Summary |
101 | Read Sub-device to Burst Message Map |
105 | Read Burst Mode Configuration |
178 | Publish Dynamic Data |
- <Parameter>: It is a number that represent each parameter of the command response. See the tables below:
Command 0 |
Parameters |
Expansion Code |
Expanded Device Type Code |
Request Preambles |
Universal Revision Level |
Transmitter Revision Level |
Software Revision |
Hardware Revision Level / Physical Signing Code |
Flags |
Device Identification Code |
Minimum# Response Preambles |
Max# of Device Variable |
Configuration Change Counter |
Extended Field Device Status |
Manufacture Identification Code |
Private Label Distributor |
Device Profile |
Command 3 |
Parameters |
PV Loop Current (many wireless devices return NaN, no analog output) |
PV Units Code |
PV |
SV Units Code |
SV |
TV Units Code |
TV |
QV Units Code |
QV |
Command 9 |
Parameters |
Slot 0: Device Variable Code |
Slot 0: Device Variable Classification |
Slot 0: Device Variable Units Code |
Slot 0: Device Variable Value |
Slot 0: Device Variable Status |
Slot 1: Device Variable Code |
Slot 1: Device Variable Classification |
Slot 1: Device Variable Units Code |
Slot 1: Device Variable Value |
Slot 1: Device Variable Status |
Slot 2: Device Variable Code |
Slot 2: Device Variable Classification |
Slot 2: Device Variable Units Code |
Slot 2: Device Variable Value |
Slot 2: Device Variable Status |
Slot 3: Device Variable Code |
Slot 3: Device Variable Classification |
Slot 3: Device Variable Units Code |
Slot 3: Device Variable Value |
Slot 3: Device Variable Status |
Slot 4: Device Variable Code |
Slot 4: Device Variable Classification |
Slot 4: Device Variable Units Code |
Slot 4: Device Variable Value |
Slot 4: Device Variable Status |
Slot 5: Device Variable Code |
Slot 5: Device Variable Classification |
Slot 5: Device Variable Units Code |
Slot 5: Device Variable Value |
Slot 5: Device Variable Status |
Slot 6: Device Variable Code |
Slot 6: Device Variable Classification |
Slot 6: Device Variable Units Code |
Slot 6: Device Variable Value |
Slot 6: Device Variable Status |
Slot 7: Device Variable Code |
Slot 7: Device Variable Classification |
Slot 7: Device Variable Units Code |
Slot 7: Device Variable Value |
Slot 7: Device Variable Status |
Slot 0: Time Stamp (units of 1/32 of a mS or 0.00003125 seconds or 31.25 μS) |
Command 13 |
Parameters |
Tag |
Descriptor |
Day |
Month |
Year since 1900 |
Command 20 |
Parameter |
Long Tag |
Command 38 |
Parameter |
Configuration Change Counter (previously read value) |
Command 48 |
Parameters |
Transmitter Status 0 |
Transmitter Status 1 |
Transmitter Status 2 |
Transmitter Status 3 |
Transmitter Status 4 |
Transmitter Status 5 |
Extended Device Status |
Device Operating Mode |
Standardize Status 0 |
Standardize Status 1 |
Analog Channel Saturated |
Standardize Status 2 |
Standardize Status 3 |
Command 50 |
Parameters |
Device Variable mapped to PV |
Device Variable mapped to SV |
Device Variable mapped to TV |
Device Variable mapped to QV |
Command 74 |
Parameters |
Maximum Number of I/O Cards (must be ≥1) |
Maximum Number of Channels per I/O Card (must be ≥1) |
Maximum Number of Sub-Devices per Channel (must be ≥1) |
Number of devices detected (the count includes the I/O system itself) |
Maximum number of delayed responses supported by the I/O system. (must be ≥ 2) |
Master mode for communication on channels. 1 = Primary Master (default) |
Retry count to use when sending commands to a sub-device. (Range 2 ≤ value ≤ 5) |
Command 84 |
Parameters |
Sub-device index |
I/O Card |
Channel |
Manufacturer Id |
Expanded Device Type Code |
Device Id |
Universal Command Revision |
Long Tag |
Device Revision |
Device Profile |
Private Label Distributor |
Command 101 |
Parameters |
Burst Message |
Sub-device Index (index 0 indicates the I/O System itself) |
Command 105 |
Parameters |
Burst Mode Control Code |
Command Number (usually 31 for HART 7 devices, see Extended Command Number) |
Device Variable Code Assigned to Slot 0 |
Device Variable Code Assigned to Slot 1 |
Device Variable Code Assigned to Slot 2 |
Device Variable Code Assigned to Slot 3 |
Device Variable Code Assigned to Slot 4 |
Device Variable Code Assigned to Slot 5 |
Device Variable Code Assigned to Slot 6 |
Device Variable Code Assigned to Slot 7 |
Burst Message |
Maximum number of burst messages supported by this device |
Extended Command Number |
Update Time (burst period) |
Maximum Update Time |
Burst Trigger Mode |
Device Variable Classification |
Trigger Units Code |
Trigger Level |
Command 178 |
Parameters |
Number of command in the structure (typically 2 for cmd 9 and cmd 48) |
Command Number 1 (typically 9) |
Command Number 1 Byte Count (varies depending on command payload) |
Command Number 1 Response code |
Extended Device Status |
PV Device Variable Code |
PV Device Variable Classification |
PV Device Variable Units Code |
PV Device Variable Value |
PV Device Variable Status |
SV Device Variable Code |
SV Device Variable Classification |
SV Device Variable Units Code |
SV Device Variable Value |
SV Device Variable Status |
TV Device Variable Code |
TV Device Variable Classification |
TV Device Variable Units Code |
TV Device Variable Value |
TV Device Variable Status |
QV Device Variable Code |
QV Device Variable Classification |
QV Device Variable Units Code |
QV Device Variable Value |
QV Device Variable Status |
PV % Range Device Variable Code (variable code = 244 typically) |
PV % Range Device Variable Classification |
PV % Range Device Variable Units Code (typically 57 = %) |
PV % Range Device Variable Value |
PV % Range Device Variable Status |
PV Loop Current Device Variable Code (variable code = 245 typically) |
PV Loop Current Device Variable Classification |
PV Loop Current Device Variable Units Code (typically 39 = mA) |
PV Loop Current Device Variable Value |
PV Loop Current Device Variable Status |
PV Time Stamp |
Command Number 2 (typically 48) |
Command Number 2 Byte Count (varies depending on command payload) |
Command Number 2 Response code |
Transmitter status byte 0 |
Transmitter status byte 1 |
Transmitter status byte 2 |
Transmitter status byte 3 |
Transmitter status byte 4 |
Transmitter status byte 5 |
Extended Device Status |
Device Operating Mode |
Standardized Status 0 |
Standardized Status 1 |
Analog Channel Saturated (usually 0) |
Standardized Status 2 |
Standardized Status 3 |