Communication Driver Name: TTS08
Implementation DLL: T.ProtocolDriver.TTS08.dll
Interface: TCPIP
Protocol: The SD50 is a TCP/IP server that supplies a binary encoded sensor data stream on port 9876 and listens for parameter tare commands on port 9976
PC Hardware requirements: Ethernet board
Channel Configuration
Protocol Options
Settings
AcceptUnsolicited must be checked
Node Configuration
Station Configuration
Station syntax: <IP>;<Port>
Where:
- <IP> = The SD50 IP Address
- <Port> = 9876 must be set to receive the data stream
Point Configuration
Address
The syntax for the TTS08 communication points are: <SensorTxId>:<ItemID>
Where:
- <SensorTxId> Sensor TxId in Hexa
- <ItemID> Specific item to be read. See the list below:
- Battery
- Pressure
- Tension
- Torque
- Temperature
- X_Axis_Acceleration
- Y_Axis_Acceleration
- Z_Axis_Acceleration
- RPM
Troubleshoot
The status of the driver's execution can be observed through the diagnostic tools, which are:
• Trace window
• Property Watch
• Module Information
The above tools indicate if the operations have succeeded or have failed. A status of 0 (zero) means communication is successful. Negative values indicate internal driver errors.