Summary Information

Communication Driver Name: TSimulator - SCADA Random Values

Current Version: 1.0.0.0

Implementation DLL: T.ProtocolDriver.TSimulator.dll



Channel Configuration

Protocol Options

Not used in this driver



Node Configuration

Not used in this driver



Point Configuration

The syntax for the TSimulator communication points is: <Type>:<Min>;<Max>


Where:

Type: Represents the Simulation Type:

For the STRING simulation type, the StringLength can be configured in the Modifiers column

Example Points Configuration


TagNameNode AddressDataTypeAccessTypeModifiers
MySineSimulatorNodeSINE:-50;50NativeRead
MyRampSimulatorNodeRAMP:0;100NativeRead
MyStringSimulatorNodeSTRING:NativeReadStringLength=5
MyBoolSimulatorNodeBOOL:NativeRead
MyIntSimulatorNodeINTEGER:0;10NativeRead
MyFloatSimulatorNodeFLOAT:-500;-100NativeRead



Troubleshoot

The status of the driver's execution can be observed through the diagnostic tools, which are:

• Trace window
• Property Watch
• Module Information

The above tools indicate if the operations have succeeded or have failed. A status of 0 (zero) means communication is successful. Negative values indicate internal driver errors, and positive values indicate protocol error codes.