Summary Information

Communication Driver Name: IPC

Implementation DLL: T.ProtocolDriver.IPC.dll

Interface: TCP/IP

PLC types supported: Filmex and Varex extrusion

Manufacturer: IPC

PC Hardware requirements: Ethernet board



Node Configuration

Station Configuration

Station syntax: <IP Address>;<Port>

Where:

E.g.: 192.168.1.1; 1505



Point Configuration

Address

The syntax for the communication points is: DB<Number>:<Word>

Where:

E.g.: DB10:5



Troubleshoot

The status of the driver's execution can be observed through the diagnostic tools, which are:

• Trace window
• Property Watch
• Module Information

The above tools indicate if the operations have succeeded or have failed. A status of 0 (zero) means communication is successful. Negative values indicate internal driver errors, and positive values indicate protocol error codes.