Audience: IT administrators and DevOps engineers deploying the product in enterprise environments (Windows Server, on-premises, or private cloud). This page is an operational workflow — install, configure, monitor, update, secure. For deep product reference, each section links to the corresponding technical page.

What You'll Deploy

A typical enterprise deployment has three layers:

For architecture context and sizing, see Platform Architecture Reference and Deployment Scenarios.

Other deployment modes (Linux, Docker/Kubernetes, edge devices, mobile clients) are supported but outside the scope of this runbook. See the links in section 10 below.

1. Plan

Before installing, decide:

2. Install

Prerequisites

Interactive install

Run the signed installer and follow the wizard. Default install location is C:\Program Files\Tatsoft\FrameworX\. Full step-by-step reference: Installation and Licensing Reference.

Silent / unattended install

The installer is an Inno Setup package and supports standard silent switches for SCCM, Intune, PowerShell DSC, Ansible, or any deployment pipeline:

Start-Process -FilePath ".\FrameworX-Setup.exe" `
  -ArgumentList "/VERYSILENT", "/SUPPRESSMSGBOXES", "/NORESTART", `
                "/LOG=C:\Logs\frameworx-install.log", `
                "/DIR=C:\Program Files\Tatsoft\FrameworX" `
  -Wait -PassThru

Replace FrameworX-Setup.exe with the name of the installer file you downloaded.

Common switches:

Switch

Purpose

/VERYSILENT

Fully silent — no progress, no prompts

/SUPPRESSMSGBOXES

Suppress all message boxes (use with /VERYSILENT)

/NORESTART

Prevent automatic reboot on completion

/DIR="<path>"

Override default install directory

/LOG="<path>"

Write install log to specified file

Install exit codes:

Code

Meaning

0

Success

1

Setup failed to initialize or user aborted

2

User cancelled during preparation

5

Install aborted (user cancelled during copy)

3010

Success — reboot required to complete

File-copy install (cross-platform runtime only)

The cross-platform runtime (.NET 10 in FrameworX 10.1.5 and 10.1.6) can also be deployed by copying the installation folder. Useful for portable deployments, custom update pipelines, and locked-down environments where MSI-style installs are blocked. See Runtime Installation Reference.

3. Configure

Install folders

Standard install layout:

Location

Purpose

C:\Program Files\Tatsoft\FrameworX\

Executables and supporting libraries (read-only after install)

C:\Users\Public\Documents\FrameworX\

User-facing content: solutions, exchange folder, screenshots, trace logs (default)

C:\ProgramData\Tatsoft\FrameworX\

Optional location for operational data when configured for enterprise deployments

Full layout reference: Installation Folders and Utilities Reference.

Run the runtime as a Windows Service

For production, the runtime should run as a Windows Service so it starts automatically with the machine, survives user logouts, and is managed through standard Windows tooling (sc.exe, Services.msc, Get-Service).

Service install options:

Command-line options, exit codes and examples: TManageServices CLI.

Run the service under a dedicated domain account where possible. The account needs:

The service has no user interface. To bring operator clients up at boot, see Installation Folders and Utilities Reference, AutoStartClient.exe.

Web server configuration

Web client, REST endpoints, and runtime HTTP services are hosted by the built-in web server. Configure ports, TLS certificates, and optional reverse-proxy routing as described in Web Server Configuration Reference.

Licensing

Online activation is used for internet-connected servers. Offline activation (license file transfer) is supported for air-gapped networks. See Licensing Procedures Reference.

Network ports

Typical enterprise deployment ports:

Port

Protocol

Service

Direction

3101

TCP

Runtime client-server

Inbound from Rich Clients

3110

HTTP

Web client (non-TLS)

Inbound from browsers

3111

HTTPS

Web client (TLS)

Inbound from browsers

4840

TCP

OPC UA Server (optional)

Inbound from OPC clients

1883 / 8883

TCP / TLS

MQTT broker (optional)

Inbound from MQTT clients

1433 / 5432 / 1521

TCP

SQL Server / PostgreSQL / Oracle

Outbound from runtime to DB

Default runtime and web ports are configurable. Exact values depend on solution configuration — see Runtime Startup Reference and Server Configuration Reference.

4. Monitor

Log locations

The runtime writes trace logs by default to C:\Users\Public\Documents\FrameworX\TraceLogs\. The location is configurable per solution via Solution Settings; enterprise deployments typically relocate it under ProgramData so it's picked up by Windows-standard log collectors (Splunk forwarder, Datadog agent, Azure Monitor, ELK).

Install logs are written to the path specified by /LOG= during silent install, or to %TEMP%\Setup Log YYYY-MM-DD.txt for interactive installs.

Service lifecycle events

Windows logs basic service start, stop, and unexpected termination events for every installed FrameworX Windows service to the System event log under source Service Control Manager. SCOM, Azure Monitor, Datadog, PRTG, and other Windows-native monitoring tools pick these up automatically without any custom configuration — point your alerts at the service name (for example, TStartup-<SolutionName>).

Application-level events (solution load failures, license errors, module exceptions) are written to the runtime TraceLogs. When an Event Log entry indicates a service failed to start, the root cause detail is in the most recent TraceLog file.

Runtime System Monitor

The built-in System Monitor exposes live metrics on tags, modules, memory, and client sessions. See Runtime System Monitor Reference and Runtime Diagnostics Reference.

5. Update & Rollback

The installer handles a letter update and a new release line in different ways:

From FrameworX 10.1.6, a move to a new release line leaves the previous release line installed, and the backup copy keeps each upgraded solution in its previous version. Full semantics: Managing Updates and Multiple Versions Reference.

Before updating a production server:

5.1 Updating a redundant pair without loss of supervision

On a hot standby pair the update is applied one node at a time, so operators keep control of the process throughout. The standby is always updated first: the node currently carrying the operators is never the node being modified.

Before the window

  1. Validate the target version in the test environment first, restoring a copy of the production solution. A test environment can load, execute and validate a production backup without licence modification.
  2. Announce the change in advance, with the planned window, the expected impact and the agreed rollback trigger.
  3. Back up the solution folder, the historian database, and the installer of the version currently running. The previous installer is the rollback artifact and must be on hand before the window opens.

Sequence

Step

Node

Action

Operator impact

1

Standby

Stop the runtime service gracefully

None. The primary carries the load

2

Standby

Run the installer with silent switches

None

3

Standby

Start the service, confirm health and synchronisation with the primary

None

4

Pair

Trigger a controlled failover to the updated node

Clients reconnect transparently

5

Former primary

Repeat steps 1 to 3 on that node

None. The updated node carries the load

6

Pair

Confirm both nodes on the same version, synchronised, and store and forward buffers drained

None

Rollback

The decision point is step 4. Until the failover is triggered the primary is untouched and still running the previous version, so rollback is limited to the standby: reinstall the previous version on it and resynchronise. Nothing reaches the operators.

If a defect appears after step 4, fail back to the node still running the previous version and reinstall on the updated one. Side by side versioning with rotation supports this by re-running the previous installer.

Rollback triggers are agreed before the window opens. Typical triggers are failure to synchronise, loss of device communication on any channel, and any discontinuity in alarm or historian data.

6. Uninstall

Uninstall from Programs & Features or silently:

"C:\Program Files\Tatsoft\FrameworX\unins000.exe" /VERYSILENT /SUPPRESSMSGBOXES /NORESTART

The uninstaller removes the installed executables, the Windows Service registration, and the registry entries. User content under C:\Users\Public\Documents\FrameworX\ is preserved — remove manually if you want a fully clean uninstall.

To remove only the installed Windows services (without removing the product files), use:

cd "C:\Program Files\Tatsoft\FrameworX"
.\TManageServices.exe /removeallservices /silent

7. Secure

Production deployments should follow the hardening checklist. Topics include TLS configuration, authentication (local users, Windows authentication, Active Directory), role-based access control, secrets storage, audit logging, and network segmentation.

8. Automate

Typical automation patterns:

9. Troubleshoot

Symptom

First place to look

Service won't start

Windows System event log (source Service Control Manager) for the service start failure; then open the most recent file in the TraceLogs folder for application-level detail

Port conflict

netstat -ano to find what's on the port; change port in Runtime Startup config

License error

Runtime TraceLogs for the detailed license error, then Licensing Procedures Reference

Client can't connect to runtime

Firewall rule on runtime port, Test-NetConnection from client, runtime client-server logs

Web client blank / auth error

TLS certificate validity, browser console, Web Server Configuration Reference

Database connection fails

Service account permissions, connection string, firewall rule to DB server

Deep reference: Runtime Troubleshooting Reference.

When opening a support ticket, collect: the most recent TraceLog file, the install log, the output of Get-Service for the runtime service, the relevant Windows System event log entries for the service, and the solution build number.

10. Other Deployment Modes

This runbook focuses on typical enterprise Windows Server deployments. Other modes are supported — see the dedicated references:

11. Remote management via SolutionCenter API

The SolutionCenter API is a JWT-authenticated REST surface for managing many FrameworX installations from a central place, planned to become available in a future FrameworX release. Each installation will expose it on port 10108 (TWebServices); central tools call it directly, and bulk fan-out happens at the orchestration layer (Ansible, PowerShell DSC, custom dashboards) rather than per-machine WinRM or shipped agents. The surface covers solution lifecycle (list/run/stop), file ops, license activation, machine settings, and runtime connection inspection.

The API cannot be enabled on 10.1.5 builds — it ships activation-gated off, and the gate cannot be opened in the 10.1.5 line, pending security hardening work scheduled for a future release. The SolutionCenter API Reference documents the API surface — scope model, endpoint catalog, and OpenAPI 3.1 document URL — for future planning.

For fleet management on 10.1.5, use the product-install-time and service-lifecycle patterns from sections 2 and 8 above (silent installer, TManageServices.exe, SCCM / Intune / PowerShell DSC). When the SolutionCenter API becomes available, it will operate one layer above — once installations exist, it will manage what runs on them.


In this section...