Connect FrameworX to an MQTT broker via Discovery Services, explore its namespace with the built-in browser, link data into the AssetTree, and build a dynamic asset-navigation UI with DataGrid, TrendChart, and AlarmViewer — all driven by Asset() bindings.
AI Integration → Platform Skills Library → Skill MQTT Integration → Skill MQTT TagProvider
Prerequisite skill: Read Skill Discovery Services first if you don't understand the difference between Device Module, DataLink, and Dynamic Tags.
Use when:
Do NOT use when:
open_solution or create_solution completed)Option A: Built-in broker for testing/demo
Navigate to Data Explorer → MQTT Tools and start the built-in services:
designer_action('navigate', 'DataExplorer.MQTTTools') |
From MQTT Tools, start the built-in broker and simulator using the tab actions:
designer_action('builtin_broker', 'start')
designer_action('simulator', 'start') |
This creates a local MQTT broker on localhost:1883 and a SparkplugB simulator publishing sample data (solar panels, cities, sensors).
Option B: External production broker
Ask the user for:
First, get the protocol schema to understand the PrimaryStation format:
get_table_schema('UnsTagProviders')
list_protocols('mqtt') |
PrimaryStation format for MQTT — 9 semicolon-separated fields (MQTTspB is 15; always confirm by calling list_protocols):
{BrokerURL};{Port};{ClientID};{UserName};{Password};{NetworkSecurity};{X509Certificate};{QoS};{KeepAlive} |
Common configurations:
| Scenario | PrimaryStation |
|---|---|
| Local built-in broker | localhost;1883;FrameworX-001;;;None;;AtLeastOnce;10 |
| Remote broker | mqtt.factory.local;1883;FrameworX-001;;;None;;AtLeastOnce;10 |
| With authentication | broker.cloud.io;8883;MyClient;admin;password123;TLSv1.2;;AtLeastOnce;30 |
Write the connection:
{
"table_type": "UnsTagProviders",
"data": [{
"Name": "MQTT",
"Protocol": "MQTT",
"PrimaryStation": "localhost;1883;FrameworX-001;;;None;;AtLeastOnce;10",
"Separators": "BranchSeparator=/;AttributeSeparator=/;",
"Description": "Production MQTT Broker"
}]
} |
For SparkplugB brokers, use MQTTspB protocol instead:
{
"Name": "SparkplugBroker",
"Protocol": "MQTTspB",
"PrimaryStation": "localhost;1883;FrameworX-SpB;;;;;None;false;;AtLeastOnce;10;false;false;true",
"Separators": "BranchSeparator=/;AttributeSeparator=/;",
"Description": "SparkplugB broker with richer metadata"
} |
Naming decision: The Name identifies the connection. A linked folder of the Asset Tree points into it with TagProviderLink set to Name.("path") (Step 2), and a tag's DataLink uses the same form. Asset() paths run from the root of the Asset Tree through the linked folder (Asset("/Production/MQTTData/...")), never from this name. Choose a meaningful name: ProductionMQTT, FactoryBroker, EdgeGateway, etc.
Separators: BranchSeparator=/;AttributeSeparator=/; maps MQTT topic hierarchy to UNS path hierarchy. This is almost always correct for MQTT.
Create an AssetTree folder that links to the Discovery Services connection. This makes the data navigable in the AssetsTree UI control.
get_table_schema('UnsAssetTree') |
{
"table_type": "UnsAssetTree",
"data": [
{ "Name": "Production" },
{
"Name": "MQTTData",
"Parent": "Production",
"TagProviderLink": "MQTT.(\"spBv1.0/GroupID\")",
"Description": "MQTT production data"
}
]
} |
Key fields:
Production/MQTTData.ProviderName.("path"), the connection Name from Step 1 and the topic branch the folder starts at. Everything below that branch appears under the folder. MQTT.("") links the entire broker namespace. There is no InitialBranch column.From this folder down, the tree is dynamic — no further configuration needed.
In displays and expressions, read a value under the folder with Asset("/Production/MQTTData/<path below spBv1.0/GroupID>"): the path runs from the root of the Asset Tree through the linked folder, never from the connection Name. In C# or VB.NET code, read the same path with TK.Data.AssetValue.
The standard asset-navigation pattern uses a Layout with three regions: Header (top), Menu (left side with AssetTree), and Content (main area).
get_table_schema('DisplaysLayouts')
list_elements('Layout') |
Read the existing startup layout first to understand current structure:
get_objects('DisplaysLayouts', detail='full', names=['Startup']) |
Write or modify the layout:
{
"table_type": "DisplaysLayouts",
"data": [{
"Name": "Startup",
"Description": "Asset navigation — tree on left, dynamic content on right",
"Members": [
{"Region": "Header", "Page": "Display.Header"},
{"Region": "Menu", "Page": "Display.AssetNav"},
{"Region": "Content", "Page": "Display.MainPage"}
]
}]
} |
Note: Startup (layout ID 0) is the predefined startup layout — it loads on application launch. Read it first before modifying to preserve any existing configuration.
A simple Canvas display with the application title and optional navigation buttons:
get_table_schema('DisplaysList')
list_elements('TextBlock,IndustrialIcon') |
{
"table_type": "DisplaysList",
"data": [{
"Type": "Display",
"Name": "Header",
"PanelType": "Canvas",
"DisplayMode": "Page",
"Width": 1200,
"Height": 60,
"Description": "Application header bar",
"Elements": [
{
"Type": "TextBlock",
"Name": "Title",
"Left": 20,
"Top": 15,
"Text": "MQTT Production Monitor",
"FontSize": 18,
"FontWeight": "Bold"
}
]
}]
} |
Use themed colors from list_elements('ThemeColors') instead of hardcoded hex values.
A Canvas display containing the AssetsTree control. When users click nodes, the platform updates Client.Context properties automatically.
list_elements('AssetsTree') |
{
"table_type": "DisplaysList",
"data": [{
"Type": "Display",
"Name": "AssetNav",
"PanelType": "Canvas",
"DisplayMode": "Page",
"Width": 300,
"Height": 700,
"Description": "Asset tree navigation panel",
"Elements": [
{
"Type": "AssetsTree",
"Name": "NavTree",
"Left": 0,
"Top": 0,
"Width": 300,
"Height": 700
}
]
}]
} |
What happens when the user clicks a node:
| Property | Description | Example value |
|---|---|---|
Client.Context.AssetPath | Path of the selected node, ending with the branch separator | Production/MQTTData/Barcelona/Panel1/ |
Client.Context.AssetName | Full name of the selected node | Production/MQTTData/Barcelona/Panel1 |
Client.Context.AssetNodeName | Leaf node name | Panel1 |
These properties drive the content display reactively — all elements bound to them update automatically.
The MainPage binds to Client.Context values to react to the user's tree selection. One display serves the entire asset hierarchy.
list_elements('DataGrid,TrendChart,TextBlock,AlarmViewer') |
Dashboard layout approach:
{
"table_type": "DisplaysList",
"data": [{
"Type": "Display",
"Name": "MainPage",
"PanelType": "Dashboard",
"Columns": 2,
"Rows": 3,
"Description": "Dynamic content — reacts to AssetTree selection",
"Elements": [
{
"Type": "TextBlock",
"Name": "AssetTitle",
"Row": 0,
"Column": 0,
"ColumnSpan": 2,
"Text": "",
"LinkedValue": "@Client.Context.AssetName",
"FontSize": 20,
"FontWeight": "Bold"
},
{
"Type": "DataGrid",
"Name": "AssetData",
"Row": 1,
"Column": 0,
"ColumnSpan": 2,
"Height": 300
},
{
"Type": "TrendChart",
"Name": "AssetTrend",
"Row": 2,
"Column": 0,
"Height": 250,
"Duration": "00:05:00"
},
{
"Type": "AlarmViewer",
"Name": "AssetAlarms",
"Row": 2,
"Column": 1,
"Height": 250
}
]
}]
} |
The key pattern — DataGrid bound to context:
The DataGrid displays all children (sub-tags and attributes) of whatever the user selected in the AssetTree. Check list_elements('DataGrid') for the exact property names to bind the DataGrid to Client.Context.AssetPath. The DataGrid automatically shows all tags below the selected path.
CodeBehind (display events):
Public Sub DisplayOpening()
' Optionally start the tree at the folder that holds the linked folder (an Asset Tree folder path)
@Client.Context.TreeInitialBranch = "Production"
End Sub |
designer_action('start_runtime') |
After starting:
Client.Context propertiesTake a screenshot to verify:
get_screenshot(target='runtime') |
| Aspect | MQTT (standard) | MQTTspB (SparkplugB) |
|---|---|---|
| Protocol name in FrameworX | MQTT | MQTTspB |
| Topic structure | Flat or custom hierarchy | spBv1.0/GroupID/NBIRTH (fixed SparkplugB convention) |
| Metadata | Topic names only | Rich: data types, birth/death certificates, metrics |
| Discovery quality | Basic (topic tree) | Full (typed variables with descriptions) |
| When to use | Generic MQTT brokers, custom topic schemes | Industrial IoT with SparkplugB-compliant edge nodes |
If the broker publishes SparkplugB messages, always prefer MQTTspB — you get typed variables and richer metadata.
Use FrameworX's built-in MQTT broker as a central data hub. External devices publish to it, and the Discovery Services connection reads from it — all on localhost.
{
"Name": "LocalHub",
"Protocol": "MQTT",
"PrimaryStation": "localhost;1883;FrameworX-Hub;;;None;;AtLeastOnce;10",
"Separators": "BranchSeparator=/;AttributeSeparator=/;",
"Description": "Built-in broker as central data hub"
} |
Start the built-in broker from Runtime Startup or via designer_action('builtin_broker', 'start').
Create multiple Discovery Services connections, each with a different Name:
{
"table_type": "UnsTagProviders",
"data": [
{"Name": "FactoryA", "Protocol": "MQTT", "PrimaryStation": "mqtt-a.factory.com;1883;..."},
{"Name": "FactoryB", "Protocol": "MQTT", "PrimaryStation": "mqtt-b.factory.com;1883;..."}
]
} |
Create separate AssetTree folders for each. The same Layout and MainPage pattern works — Client.Context handles any source.
Use Discovery Services for browsing the full MQTT namespace, but create local tags with DataLink for the few points that need alarms and historian:
{
"table_type": "UnsTags",
"data": [
{
"Name": "Critical/ReactorTemp",
"Type": "Double",
"DataLink": "MQTT.(\"plant/reactor/temperature\")",
"Min": 0,
"Max": 500,
"Description": "Reactor temperature — alarmed and historized"
}
]
} |
Then configure alarms and historian on Critical/ReactorTemp as a normal tag. The DataLink binds it to the MQTT topic automatically. DataLink is written ProviderName.("path"); /Provider/path and Provider/path do not link.
If connecting to a historian-capable Discovery Services connection (Canary, InfluxDB, etc.), TrendCharts using Asset() syntax query historical data for the selected time range. The connection row has no IsHistorian column; the protocol driver declares the capability.
| Mistake | Why it happens | How to avoid |
|---|---|---|
| Creating local UnsTags for MQTT data | Habit from Device Module workflow | Dynamic tags don't need local tags. Only use DataLink for points needing alarms/historian. |
| Wrong PrimaryStation format | Forgetting semicolons or field order | Always call list_protocols('mqtt') first — the format is 9 semicolon-separated fields (15 for MQTTspB). |
| Topics with special chars not accessible | MQTT topics like spBv1.0/GroupID contain dots | Keep the topic inside a quoted string: MQTT.("spBv1.0/GroupID") in TagProviderLink, and Asset("/Production/MQTTData/Barcelona/Panel1") in displays and expressions. The path runs from the root of the Asset Tree through the linked folder, not from the connection Name. |
| AssetTree empty after runtime start | Connection not established or linked folder misconfigured | Check Services Monitor for connection status. Verify that TagProviderLink is <connection Name>.("path") and that the linked folder has a Parent folder. |
| Using MQTT protocol for SparkplugB broker | SparkplugB has specific message format | Use MQTTspB protocol for SparkplugB brokers — you get typed variables and metadata. |
| DataGrid shows nothing | Not bound to Client.Context properly | Check list_elements('DataGrid') for the correct binding properties. |
| Trying to set alarms on dynamic tags | No local tag exists for dynamic data | Create a local tag with DataLink for that specific path, then configure alarms on it. |
| Task | Tool call |
|---|---|
| Get MQTT protocol format | list_protocols('mqtt') |
| Get SparkplugB format | list_protocols('mqtt sparkplug') |
| Create Discovery Services connection | write_objects('UnsTagProviders', data=[...]) |
| Create AssetTree linked folder | write_objects('UnsAssetTree', data=[...]) |
| Browse AssetsTree element schema | list_elements('AssetsTree') |
| Browse DataGrid schema | list_elements('DataGrid') |
| Navigate to MQTT Tools | designer_action('navigate', 'DataExplorer.MQTTTools') |
| Start built-in broker | designer_action('builtin_broker', 'start') |
| Start built-in simulator | designer_action('simulator', 'start') |
| Check runtime state | get_state(target='runtime') |
| Navigate to Services Monitor | designer_action('navigate', 'ServicesMonitor') |