Level 2 advanced control with .NET DLL integration for steel slab reheating optimization.
Industry: Steel and Materials


Quick Facts

AttributeValue
Scale200,000+ internal tags
Furnaces5 reheating furnaces
PLCsSiemens controllers
IntegrationSAP, LIMAB Laboratory, TCP/IP Level 1
ArchitectureLevel 2 control with .NET DLL algorithms
Operation24x7 continuous steel processing

The Challenge

Challenge: Implement Level 2 advanced control system for steel slab reheating across 5 furnaces with precise temperature control, fuel optimization, and full integration with SAP and laboratory systems.

Specific pain points:

  • Steel slabs require precise temperature control for different alloy types and applications
  • Manual recipe management inefficient for 24x7 operations
  • Lack of integrated control between charging, tracking, and discharging processes
  • Need for fuel optimization while maintaining product quality
  • Disconnected systems between SAP, laboratory data, and Level 1 control

Impact: Inefficient furnace operation leading to increased fuel consumption, quality variations, and limited production throughput in continuous steel processing operations.


The Solution

Architecture

TierComponentCapabilities
Level 1Siemens PLCs (5 furnaces)Real-time furnace control
Level 2FrameworX EnterpriseAdvanced control algorithms, recipe management
.NET DLL LayerCustom algorithmsTemperature and fuel optimization
IntegrationSAP, LIMAB LabRecipe data, quality feedback
ClientsControl room + field stations24x7 operator interface

Simplified diagram:

<svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 500 420" width="100%" style="max-width:500px;" preserveAspectRatio="xMidYMid meet">
  <style>
    .box { fill: #f0f7ff; stroke: #1a5276; stroke-width: 2; rx: 8; }
    .box-purple { fill: #f5eef8; stroke: #8e44ad; stroke-width: 2; rx: 8; }
    .box-green { fill: #e8f6f3; stroke: #1abc9c; stroke-width: 2; rx: 8; }
    .box-orange { fill: #fef5e7; stroke: #e67e22; stroke-width: 2; rx: 8; }
    .label { font-family: Arial, sans-serif; font-size: 13px; font-weight: bold; fill: #2c3e50; }
    .sublabel { font-family: Arial, sans-serif; font-size: 11px; fill: #7f8c8d; }
    .line { stroke: #34495e; stroke-width: 2; }
    .arrow { fill: #34495e; }
  </style>
  
  <!-- Background -->
  <rect width="100%" height="100%" fill="#fafbfc"/>
  
  <!-- Operator Stations -->
  <rect x="150" y="15" width="200" height="45" class="box-purple"/>
  <text x="250" y="35" text-anchor="middle" class="label">Operator Stations</text>
  <text x="250" y="52" text-anchor="middle" class="sublabel">Control Room + Field</text>
  
  <!-- Arrow down -->
  <line x1="250" y1="60" x2="250" y2="80" class="line"/>
  <polygon points="250,88 245,80 255,80" class="arrow"/>
  
  <!-- FrameworX Enterprise -->
  <rect x="125" y="90" width="250" height="45" class="box"/>
  <text x="250" y="110" text-anchor="middle" class="label">FrameworX Enterprise</text>
  <text x="250" y="127" text-anchor="middle" class="sublabel">(Level 2 Control)</text>
  
  <!-- Arrow down -->
  <line x1="250" y1="135" x2="250" y2="155" class="line"/>
  <polygon points="250,163 245,155 255,155" class="arrow"/>
  
  <!-- .NET DLL Layer -->
  <rect x="100" y="165" width="300" height="45" class="box-green"/>
  <text x="250" y="185" text-anchor="middle" class="label">.NET DLL Layer</text>
  <text x="250" y="202" text-anchor="middle" class="sublabel">(Temperature & Fuel Algorithms)</text>
  
  <!-- Arrow down -->
  <line x1="250" y1="210" x2="250" y2="230" class="line"/>
  <polygon points="250,238 245,230 255,230" class="arrow"/>
  
  <!-- Integration Layer -->
  <rect x="125" y="240" width="250" height="45" class="box-orange"/>
  <text x="250" y="260" text-anchor="middle" class="label">Integration Layer</text>
  <text x="250" y="277" text-anchor="middle" class="sublabel">200,000+ Tags</text>
  
  <!-- Arrow down to branch -->
  <line x1="250" y1="285" x2="250" y2="305" class="line"/>
  
  <!-- Horizontal branch line -->
  <line x1="80" y1="305" x2="420" y2="305" class="line"/>
  
  <!-- SAP branch -->
  <line x1="80" y1="305" x2="80" y2="325" class="line"/>
  <polygon points="80,333 75,325 85,325" class="arrow"/>
  <rect x="30" y="335" width="100" height="35" class="box"/>
  <text x="80" y="358" text-anchor="middle" class="label">SAP</text>
  
  <!-- Siemens PLCs branch (center) -->
  <line x1="250" y1="305" x2="250" y2="325" class="line"/>
  <polygon points="250,333 245,325 255,325" class="arrow"/>
  <rect x="175" y="335" width="150" height="45" class="box"/>
  <text x="250" y="355" text-anchor="middle" class="label">Siemens PLCs</text>
  <text x="250" y="372" text-anchor="middle" class="sublabel">(5 Furnaces)</text>
  
  <!-- LIMAB Lab branch -->
  <line x1="420" y1="305" x2="420" y2="325" class="line"/>
  <polygon points="420,333 415,325 425,325" class="arrow"/>
  <rect x="360" y="335" width="120" height="35" class="box"/>
  <text x="420" y="358" text-anchor="middle" class="label">LIMAB Lab</text>
  
  <!-- TCP/IP Level 1 (below Siemens) -->
  <line x1="250" y1="380" x2="250" y2="395" class="line"/>
  <polygon points="250,403 245,395 255,395" class="arrow"/>
  <text x="250" y="415" text-anchor="middle" class="sublabel">TCP/IP Level 1</text>
</svg>


Core Functionality

FunctionDescription
Charging ControlWeight validation, measurement, SAP data verification
In-Furnace TrackingReal-time slab position and status monitoring
Discharging ControlCoordinated slab extraction and handoff
Temperature CalculationAdvanced algorithms for optimal heating profiles
Fuel OptimizationMinimized consumption while maintaining quality

Connectivity

SystemProtocol/Interface
Siemens PLCsTCP/IP Level 1 integration
SAPEnterprise integration
LIMAB LaboratoryProprietary laboratory system interface

Key Enablers

FrameworX capabilities that made this solution possible:

CapabilityApplication
.NET DLL IntegrationNative support for custom control algorithms (migrated from C++)
Massive Tag Management200,000+ tags with real-time performance
Multi-Protocol SupportSiemens PLCs, TCP/IP Level 1, laboratory interfaces
Advanced UI ComponentsComplex grids with color-coding for slab status and positioning
24x7 ReliabilityContinuous operation for steel production



The Results

  • Unified Furnace Control — Achieved integrated control across 5 furnaces from single platform
  • Real-time Slab Tracking — Enabled tracking of all slabs through complete furnace cycle
  • Optimized Fuel Consumption — Reduced fuel usage through advanced temperature algorithms
  • 24x7 Reliability — Maintained continuous operation for steel production
  • System Integration — Connected previously disconnected SAP, Laboratory, and Level 1 systems
  • Algorithm Migration — Successfully migrated C++ algorithms to .NET DLLs within FrameworX

This case demonstrates Level 2 advanced control for steel reheating furnaces with .NET DLL algorithm integration and enterprise system connectivity.