Level 2 advanced control with .NET DLL integration for steel slab reheating optimization.
Industry: Steel and Materials
| Attribute | Value |
|---|---|
| Scale | 200,000+ internal tags |
| Furnaces | 5 reheating furnaces |
| PLCs | Siemens controllers |
| Integration | SAP, LIMAB Laboratory, TCP/IP Level 1 |
| Architecture | Level 2 control with .NET DLL algorithms |
| Operation | 24x7 continuous steel processing |
Challenge: Implement Level 2 advanced control system for steel slab reheating across 5 furnaces with precise temperature control, fuel optimization, and full integration with SAP and laboratory systems.
Specific pain points:
Impact: Inefficient furnace operation leading to increased fuel consumption, quality variations, and limited production throughput in continuous steel processing operations.
| Tier | Component | Capabilities |
|---|---|---|
| Level 1 | Siemens PLCs (5 furnaces) | Real-time furnace control |
| Level 2 | FrameworX Enterprise | Advanced control algorithms, recipe management |
| .NET DLL Layer | Custom algorithms | Temperature and fuel optimization |
| Integration | SAP, LIMAB Lab | Recipe data, quality feedback |
| Clients | Control room + field stations | 24x7 operator interface |
<svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 500 420" width="100%" style="max-width:500px;" preserveAspectRatio="xMidYMid meet">
<style>
.box { fill: #f0f7ff; stroke: #1a5276; stroke-width: 2; rx: 8; }
.box-purple { fill: #f5eef8; stroke: #8e44ad; stroke-width: 2; rx: 8; }
.box-green { fill: #e8f6f3; stroke: #1abc9c; stroke-width: 2; rx: 8; }
.box-orange { fill: #fef5e7; stroke: #e67e22; stroke-width: 2; rx: 8; }
.label { font-family: Arial, sans-serif; font-size: 13px; font-weight: bold; fill: #2c3e50; }
.sublabel { font-family: Arial, sans-serif; font-size: 11px; fill: #7f8c8d; }
.line { stroke: #34495e; stroke-width: 2; }
.arrow { fill: #34495e; }
</style>
<!-- Background -->
<rect width="100%" height="100%" fill="#fafbfc"/>
<!-- Operator Stations -->
<rect x="150" y="15" width="200" height="45" class="box-purple"/>
<text x="250" y="35" text-anchor="middle" class="label">Operator Stations</text>
<text x="250" y="52" text-anchor="middle" class="sublabel">Control Room + Field</text>
<!-- Arrow down -->
<line x1="250" y1="60" x2="250" y2="80" class="line"/>
<polygon points="250,88 245,80 255,80" class="arrow"/>
<!-- FrameworX Enterprise -->
<rect x="125" y="90" width="250" height="45" class="box"/>
<text x="250" y="110" text-anchor="middle" class="label">FrameworX Enterprise</text>
<text x="250" y="127" text-anchor="middle" class="sublabel">(Level 2 Control)</text>
<!-- Arrow down -->
<line x1="250" y1="135" x2="250" y2="155" class="line"/>
<polygon points="250,163 245,155 255,155" class="arrow"/>
<!-- .NET DLL Layer -->
<rect x="100" y="165" width="300" height="45" class="box-green"/>
<text x="250" y="185" text-anchor="middle" class="label">.NET DLL Layer</text>
<text x="250" y="202" text-anchor="middle" class="sublabel">(Temperature & Fuel Algorithms)</text>
<!-- Arrow down -->
<line x1="250" y1="210" x2="250" y2="230" class="line"/>
<polygon points="250,238 245,230 255,230" class="arrow"/>
<!-- Integration Layer -->
<rect x="125" y="240" width="250" height="45" class="box-orange"/>
<text x="250" y="260" text-anchor="middle" class="label">Integration Layer</text>
<text x="250" y="277" text-anchor="middle" class="sublabel">200,000+ Tags</text>
<!-- Arrow down to branch -->
<line x1="250" y1="285" x2="250" y2="305" class="line"/>
<!-- Horizontal branch line -->
<line x1="80" y1="305" x2="420" y2="305" class="line"/>
<!-- SAP branch -->
<line x1="80" y1="305" x2="80" y2="325" class="line"/>
<polygon points="80,333 75,325 85,325" class="arrow"/>
<rect x="30" y="335" width="100" height="35" class="box"/>
<text x="80" y="358" text-anchor="middle" class="label">SAP</text>
<!-- Siemens PLCs branch (center) -->
<line x1="250" y1="305" x2="250" y2="325" class="line"/>
<polygon points="250,333 245,325 255,325" class="arrow"/>
<rect x="175" y="335" width="150" height="45" class="box"/>
<text x="250" y="355" text-anchor="middle" class="label">Siemens PLCs</text>
<text x="250" y="372" text-anchor="middle" class="sublabel">(5 Furnaces)</text>
<!-- LIMAB Lab branch -->
<line x1="420" y1="305" x2="420" y2="325" class="line"/>
<polygon points="420,333 415,325 425,325" class="arrow"/>
<rect x="360" y="335" width="120" height="35" class="box"/>
<text x="420" y="358" text-anchor="middle" class="label">LIMAB Lab</text>
<!-- TCP/IP Level 1 (below Siemens) -->
<line x1="250" y1="380" x2="250" y2="395" class="line"/>
<polygon points="250,403 245,395 255,395" class="arrow"/>
<text x="250" y="415" text-anchor="middle" class="sublabel">TCP/IP Level 1</text>
</svg> |
| Function | Description |
|---|---|
| Charging Control | Weight validation, measurement, SAP data verification |
| In-Furnace Tracking | Real-time slab position and status monitoring |
| Discharging Control | Coordinated slab extraction and handoff |
| Temperature Calculation | Advanced algorithms for optimal heating profiles |
| Fuel Optimization | Minimized consumption while maintaining quality |
| System | Protocol/Interface |
|---|---|
| Siemens PLCs | TCP/IP Level 1 integration |
| SAP | Enterprise integration |
| LIMAB Laboratory | Proprietary laboratory system interface |
FrameworX capabilities that made this solution possible:
| Capability | Application |
|---|---|
| .NET DLL Integration | Native support for custom control algorithms (migrated from C++) |
| Massive Tag Management | 200,000+ tags with real-time performance |
| Multi-Protocol Support | Siemens PLCs, TCP/IP Level 1, laboratory interfaces |
| Advanced UI Components | Complex grids with color-coding for slab status and positioning |
| 24x7 Reliability | Continuous operation for steel production |
This case demonstrates Level 2 advanced control for steel reheating furnaces with .NET DLL algorithm integration and enterprise system connectivity.