Version 10.1 or newer represents a major advancement with simplified concepts and new technologies. While most legacy projects upgrade smoothly, 100% compatibility cannot be guaranteed. All upgraded projects require validation in a lab environment before production deployment.
| Source Version | Direct Upgrade | Process |
|---|---|---|
| 8.1, 9.1, 9.2 | Yes | Direct upgrade to 10.1 or newer |
| Earlier than 8.1 | No | First upgrade to 8.1/9.1/9.2, then to 10.1 or newer |
All projects must be revalidated in a lab environment before field deployment. This step is essential to confirm optimal functionality in the new version.
<project>.tproj file in SolutionCenter folder.dbsln file with same name.tproj file remains intact| Action | Result |
|---|---|
| Original file | Preserved unchanged |
| New solution | Created as .dbsln |
| Solution List | Shows only new .dbsln |
| Legacy file | Hidden from list |
Starting with 10.1.5, every upgrade creates a preserved backup of the original solution file next to the solution itself. You do not need to copy the file manually before running the upgrade. The backup filename encodes the source version.
For example, upgrading Plant.dbsln from an earlier 10.1.x release leaves your solution folder containing:
File | Content |
|---|---|
| The upgraded solution. Open this one in the Designer. |
| Preserved snapshot of the pre-upgrade solution. Safe to delete once the upgrade is validated in your lab environment. |
Legacy .tproj upgrades continue to behave the same as in earlier releases: the original .tproj file stays on disk untouched and acts as its own rollback copy.
When an upgrade does not complete successfully, 10.1.5 guarantees:
The Solution Center displays a failure dialog that includes the full path to the upgrade log file (typically %PUBLIC%\Documents\FrameworX\TraceLogs\UpgradeLog.txt). Open the log to see the exception detail that caused the failure.
From FrameworX 10.1.6, opening a solution from an earlier version always saves a backup copy of the file before the upgrade. If FrameworX fails to write the backup copy, for example because the disk is full or the resulting path is too long, it refuses to open the solution instead of upgrading it without a safety copy. The message names the solution, the backup file and the reason.
A solution from an earlier version no longer opens when its backup copy cannot be written. If the message reports a backup failure, free disk space, shorten the folder path, or move the solution to a writable folder, then open it again. A solution opened read-only is not upgraded. To upgrade it, make the file and its folder writable and open it again. |
An upgrade can complete successfully while still logging individual non-fatal warnings — for example, a single table cell whose legacy value cannot be mapped to the new schema. When this happens, the Solution Center displays a count on the Upgrade Concluded dialog:
N exception(s) logged during upgrade. Open log file
Click Open log file to launch the upgrade log in your default text editor. Each logged entry includes:
CopyMembers cell convert [DisplaysListContents.Xaml]).Review the logged warnings as part of your pre-production validation. Most are informational — a row or cell that could not be automatically migrated — and can be resolved by hand in the Designer after the upgrade.
Solutions that upgraded silently on 10.1.4 and earlier may show a non-zero warning count on 10.1.5. This is a visibility change, not a behavioral one — the same legacy data condition was being silently skipped before. The upgrade still succeeds in the same scenarios it did before. |
The headless upgrade utility UpgradeSolution.exe (shipped in the FrameworX program folder) prints exception details directly to the console instead of surfacing only the aggregate count. Typical output:
> UpgradeSolution.exe "C:\Projects\Plant.dbsln" Upgrading: C:\Projects\Plant.dbsln Previous version: fs-10.1.4-12345 Backup file: C:\Projects\Plant_fs-10.1.dbsln [ 5%] Preparing table 'UserTypesContents'... [ 78%] Copying source tables to target... Upgrade finished. Exceptions during upgrade: 1 --- UpgradeLog.txt (this run) --- 2026-04-21 10:32:14 ****** Upgrade started: C:\Projects\Plant.dbsln ****** 2026-04-21 10:32:16 Exception on CopyMembers cell convert [DisplaysListContents.Xaml]: ... 2026-04-21 10:35:02 ****** Upgrade finished: C:\Projects\Plant.dbsln ****** --- end of log --- Full log: C:\Users\Public\Documents\FrameworX\TraceLogs\UpgradeLog.txt |
Exit codes:
Code | Meaning |
|---|---|
| Successful upgrade. Non-fatal warnings may have been logged; check the tail output. |
| Fatal upgrade failure. Original file is preserved; backup file is preserved. |
| Invalid command-line arguments. |
Issue: Table name change from EditSecurityUsers_Runtime to SecurityRuntimeUsers
Required Action:
EditSecurityUsers_RuntimeSecurityRuntimeUsersApplications using programmatic engineering (EngWrapper API) may lack compatibility due to internal structure changes. Contact support for upgrade assistance.
| Version | Approach | Migration |
|---|---|---|
| 9.2 | Complex customization | Manual review required |
| 10 | Simplified interface | Cannot fully automate |
Review screens and objects mapped to theme resources after upgrade.
Version 10.1 or newer uses async programming patterns for improved performance and HTML5 compatibility.
C# Example:
public async Task DisplayOpening()
{
await @Script.Class.ServerMain.Method1();
} |
VB.NET Example:
Public Async Function DisplayOpening() As Task
Await @Script.Class.ServerMain.Method1()
End Function |
Replace LogOn() with LogOnAsync():
JavaScript:
this.DialogOnOK = async function()
{
var result = await @Client.LogOnAsync("user1", "pass1");
return true;
}; |
C#:
public async Task<bool> DialogOnOK()
{
var result = await @Client.LogOnAsync("user1", "pass1");
return true;
} |
VB.NET:
Public Async Function DialogOnOK() As Task(Of Boolean)
Dim result As Integer = Await @Client.LogOnAsync("user1", "pass1")
Return True
End Function |
Legacy Code (Synchronous):
Public Function DialogOnOK() As Boolean
Dim log As eSecurityErrors
log = DirectCast(@Client.LogOn(@Client.InputUserName, @Client.InputPassword), eSecurityErrors)
If log = eSecurityErrors.OK Then
@Display.LogOn.Close()
Return True
End If
Return False
End Function |
Updated Code (Async):
Public Async Function DialogOnOK() As Task(Of Boolean)
Dim log As eSecurityErrors
log = DirectCast(Await @Client.LogOnAsync(@Client.InputUserName, @Client.InputPassword), eSecurityErrors)
If log = eSecurityErrors.OK Then
@Display.LogOn.Close()
Return True
End If
Return False
End Function |
All mnemonics require default values:
| Version | Format | Example |
|---|---|---|
| Legacy | #HourOfDay: | Missing default |
| 10.1 or newer | #HourOfDay:"" | Includes default |
Use Drawing Properties for positioning:
| Feature | Legacy | 10.1 or newer |
|---|---|---|
| Method | Docking/alignment | New layout system |
| Multi-level menus | Multiple docked windows | Single header window |
| Submenus | Separate windows | ChildDisplay controls |
Projects from 9.2 or older versions that did not use the last screen in the layout list as the dynamic screen, which automatically switched screens with an open command and therefore needed to use the OpenAtIndex command, must have their layouts reconfigured, because in a migration to 10.1 or newer, the last screen in the layout list will be considered the main switching screen.
Display WPF only no longer automatically converts LayoutTransform (rotation used in 8.1 version that doesn't work for HTML5) to RenderTransform (rotation used in v10 that is used for WPF and HTML5), it keeps as LayoutTransform. However, if the user ungroups symbols, groups, and shape groups that have LayoutTransform, or removes the Transform, the LayoutTransform will be lost.
| Feature | Status | Alternative |
|---|---|---|
| Synchronous SQL calls | Warning issued | Use async methods |
| Custom theme editing | Not supported | Use standard themes |
<TagProvider>.("Topic Path") syntax | Removed | Map to AssetTree |
| XPS documents | Not supported | Use PDF or other formats |
| Issue | Solution |
|---|---|
| Display errors | Update async methods in CodeBehind |
| Database failures | Rename RuntimeUsers table |
| Theme problems | Review color mappings |
| Layout issues | Redesign using new system |