Connect UNS to external data services.

Reference → Modules → UNS → UI → Asset | Tags | UserTypes | Enumerations | Services | Monitor


UNS TagProvider Services (Reference) enable direct interaction with variables in remote systems. TagProvider Services provide:

  • Dynamic external data access through auto-discovery
  • Three connection patterns: Local Tags, Linked Tags (via DataLink), and Dynamic Tags (via Asset() syntax)
  • Automatic data model discovery at runtime
  • On-demand communication — activated when data is consumed, released when not
  • Multi-protocol support (~16 discovery-capable connectors)

TagProviders allow consuming external data models directly, ideal for IoT systems and dynamic environments where device configurations change frequently.



Find a TagProvider Service


TagProviders vs Devices

Both TagProvider Services and the Devices module connect FrameworX to external systems. They are completely independent — they share nothing architecturally. Some protocols (MQTT, OPC UA, ControlLogix) are available in both, with different workflows.

Aspect

Devices Module

TagProvider Services

Design philosophy

Define explicitly, validate strictly

Auto-discover, bind dynamically

Tag creation

Required — every point maps to a local tag

Optional — Dynamic Tags need no pre-created tags

Namespace control

Solution architect defines everything

External source can define structure

Metadata

Full control (alarms, historian, scaling, units)

Full on Linked Tags; limited on Dynamic Tags

Security

Granular per tag

Connection level

Available protocols

~100 (all industrial protocols)

~16 (discovery-capable only)

Configuration

Design-time

Runtime discovery

Best for

SCADA control, regulatory compliance, FDA

IIoT monitoring, dynamic environments, UNS integration

Can coexist?

Yes — same solution, even same protocol

Yes


Supported TagProviders

Communication Protocols

Database Connectors

Application Integration

Enterprise Historians

Some connectors (Canary, InfluxDB, GE Proficy, SQL, MongoDB) can also serve as Storage Locations in the Historian module for archiving time-series data. That is a separate configuration in the Historian module — see Historian for details.


Configuration

Creating a Connection

  1. Navigate to Unified Namespace → TagProvider Services
  2. Click New Item
  3. Select protocol from the list
  4. Set the ServiceType: Tag Discovery (default) or Extension Module
  5. Configure connection parameters (PrimaryStation is protocol-specific — use list_protocols in MCP)
  6. The connection appears in the Services grid. No Asset Tree folder is created: to use the data with Asset(), select a folder in the Asset Tree (create one first if needed) and click Insert data from TagProvider on the Asset Tree toolbar. The folder linked to the TagProvider is created inside the selected folder.

All Properties

Property

Type

Required

Description

Name

String

Yes

Unique connection identifier

Protocol

Reference

Yes

Communication protocol (references DevicesProtocols)

PrimaryStation

String

Yes

Main connection endpoint — format is protocol-specific

ServiceType

Enum

No

TagDiscovery (default), ExtensionModule or HistorianStorage (the provider is a Historian Storage Location)

Description

String

No

Connection description

BackupStation

String

No

Redundant endpoint for failover

FailOverStation

String

No

Failover connection string

ProtocolOptions

String

No

Protocol-specific configuration — format is protocol-specific

Settings

String

No

Additional connection settings

Timeout

String

No

Connection timeout value

Access

String

No

Access mode configuration

ReadTime

String

No

Read polling rate

WriteTime

String

No

Write rate

GatewayIP

String

No

Address of the gateway computer that opens the provider connection, as host:port of its TWebServices (Solution Center) service. The default port is 10108 and the port is required. Empty connects from the runtime computer.

Interface

String

No

Network interface binding

InitialState

String

No

Initial state at runtime startup (enabled/disabled)

RemoteSettings

String

No

Remote connection configuration

Separators

String

No

Tag path separator configuration

DriverVersion

String

No

Protocol driver version

Category

String

No

Classification group for organizing connections

Separators per provider

Connector

Branch

Attribute

MQTT, MQTT Sparkplug B, Sorba AI

/

/

OPC UA

\

\

PI, GE Proficy, Value Simulator

\

|

ControlLogix, TwinCAT, PLC Handler, MongoDB, QuestDB, SQL Database, SQL Database Normalized, Canary

.

.

InfluxDB, FlowTimebaseDB, LineMonitor

|

|

These are the defaults. An OPC UA connection can set its own branch separator in its station settings, and the TagProvider then uses that one. To set separators through the AI tools, write BranchSeparator=<char>;AttributeSeparator=<char>; in the Separators column. Leave it out to keep the stored value. A TagProvider named MQTT or CanaryLabs ignores the column.


PrimaryStation, BackupStation, and ProtocolOptions formats vary by protocol. Always call list_protocols (MCP) or check the specific connector reference page before configuring these fields.


Protocol-Specific Settings

OPC UA

Setting

Description

Server URL

OPC UA endpoint (e.g. opc.tcp://server:4840)

Security Policy

None, Basic128Rsa15, Basic256, Basic256Sha256

Security Mode

None, Sign, SignAndEncrypt

Authentication

Anonymous, Username/Password, Certificate

MQTT

Setting

Description

Broker

MQTT broker address

Port

Broker port (default: 1883)

Topic Structure

Topic pattern for subscription

QoS

Quality of Service level (0, 1, 2)

Client ID

Unique client identifier

ControlLogix

Setting

Description

IP Address

PLC IP address

Slot

CPU slot number

Path

Optional routing path

SQL Database

Setting

Description

Connection String

Database connection string

Query

SQL query for data retrieval

Refresh Rate

Poll interval (ms)

MongoDB

Setting

Description

PrimaryStation

Semicolon-delimited: ConnectionUri;Database;AuthSource;TlsEnabled. Example: mongodb://localhost:27017;plant_data;admin;false

Discovery

Level 0 lists collections; Level 1 samples the latest document and lists top-level field names. _id is hidden.

Address format

Single-dot collection.field. Multi-dot rejected in 10.1.5.

Read / Write

Read returns latest document field (Quality 192 on hit, 0 on miss). Write applies $set on the most-recent document.


DataLink Property

DataLink is a property on UnsTags — not on the TagProvider connection itself. When set on a tag, it binds that tag to a path in a TagProvider's discovered namespace.

Example: A tag Plant/Tank1/Temperature with DataLink set to MyMQTT.("sensors/tank1/temp") will automatically receive values from the MQTT broker whenever the tag is read. Communication is on-demand — activated when consumed, released when not.

This is the mechanism behind Linked Tags — tags that exist in the local UNS with full metadata (alarms, historian, scaling) but get their values from an external source.

See UNS Tag Discovery Reference for the full explanation of Local Tags, Linked Tags, and Dynamic Tags patterns.


Asset() Syntax Reference

Basic Syntax

Asset("/Plant/<linked folder>/<path on the TagProvider>")

Plant is a folder of the Asset Tree, and the linked folder is a folder under it that is linked to the TagProvider's root. The linked folder sits inside a folder of the Asset Tree, not at its root.

After the linked folder, write the path with the TagProvider's own separator. On a provider that separates with \, a folder linked to its root reads Asset("/Plant/Provider/Area\Tag") in a display or an expression, and a folder linked to Area reads Asset("/Plant/Provider\Tag"). C# and VB.NET code reads the same path with TK.Data.AssetValue. In C#, double each backslash in the string: TK.Data.AssetValue("/Plant/Provider/Area\\Tag"). In VB.NET, write each backslash once: TK.Data.AssetValue("/Plant/Provider/Area\Tag"). MQTT uses /. See separators per provider.

ControlLogix Syntax

MyPLC is a folder under Plant linked to the ControlLogix TagProvider's root.

Asset("/Plant/MyPLC/DataType:TagName")
Asset("/Plant/MyPLC/DINT:MyTag")
Asset("/Plant/MyPLC/DINT:MyArray[0]")
Asset("/Plant/MyPLC/REAL:Temperature")

Supported Operations

Operation

Syntax

Read in a display or an expression

Asset("/path")

Read in C# or VB.NET code

TK.Data.AssetValue("/path")

Subscribe

Automatic in displays


Data Type Handling

TK.Data.AssetValue returns the value as an object. Convert it to the type the code needs:

Method

Returns

TK.ToInt(value)

Integer

TK.ToDouble(value)

Double

TK.ToString(value)

String

TK.ToBool(value)

Boolean

TK.ToDateTime(value)

DateTime


Access Modes

Mode

Description

Read

Read-only access to external data

Write

Write-only access. A provider used as a historian storage location needs Write or ReadWrite to store samples.

ReadWrite

Full bidirectional access

From FrameworX 10.1.6, a value written to a TagProvider tag through a gateway (GatewayIP) reaches the device. The gateway computer must also run FrameworX 10.1.6. Writes to PI points through a gateway are not supported.


See Also